Quakertown PA Commercial Refrigeration

K&D Factory Service Inc. has been bringing OEM commercial cooking parts and service to restaurants and commercial kitchens of Quakertown, PA and the surrounding areas since 1945!

Read our reviews and find out why your colleagues consider us to be their nearby commercial cooking supply company in Quakertown, PA.

Recent Jobs and Reviews in Quakertown, PA

Job Locations and Reviews

Mark B.
Mark B. Checked in
Commercial Kitchen Appliance Repair Service. Arrived at the location on 4/26/23 for commercial oven repairs - Inspected left oven as customer states door springs are broken found the right spring broken will order two new springs and return to install. Returned to the location on 4/28/23 - Arrived and disassemble and removed the bad door spring from the left oven. Installed 2 new door springs and adjusted the door to close fully and open them properly. Tested operation and oven fan comes on with the door closed and off when the door is open. The oven burner is on. The unit is back in service.
Quakertown, PA 18951
Mark B.
Mark B. Checked in
Arrived at location on 7/26/22 - Found leak at pressure gauge. Was leaking thru gauge. Removed gauge and plugged with 1/2 “ plug. Left reducer there for gauge. 1/4 x 1/2. Tested for leaks and chemical tube at injector manifold was leaking. Tightened nut and it stopped. No more leaks found. Will order part and return. Unit is operational but requires part. Returned to location on 8/1/22 - Removed plug I put in so they could use it. Installed new pressure gauge. Turned up water on and tested unit. No leaks and unit operated properly. Unit is operational job complete.
Quakertown, PA 18951
Mark B.
Mark B. Checked in
Arrived at location on 7/20/21 - checked unit ,h.s.i glows and pulls 2.7 amps, but module not sending 24v to has valve. Plugged new hot surface igniter in and let hang out in air touching frame to ground. Had 2.8 amps on start up but still no voltage to gas valve. Checked all wiring in Molex plug and they are good. Tested all connections to module and to gas valve. All good. Called southbend spoke to charles, explained all I did. He said it has to be module. Will obtain and return. unit down requires parts.
Quakertown, PA 18951
Service C.
Service C. Checked in
Tested the CLE Kettle Unit incoming gas pressure and it is moving around a lot. As low as 6.90 " to 10.5 " wc . Took A 30 second video of incoming pressure and showed it to Iris and Glen in maintenance. Glen will have the regulator in the boiler room looked at again. Something is not controlling the pressure to the kettles. Tested the manifold pressure and adjusted it down so it didn't go over 3.8 the lowest I can get it. Manifold pressure as low a 1.1 to 3.8 " wc now . Ran the boiler and the pressure relief valve started to open at 13.5 Psi and burner didn't shut off. Found the operating pressure switch was adjusted to hi. Lower it to operate between 7 and 10 psi and allow it to cycle many many times without fail. Had water in the kettles and both come to a boil. Unit ok and in service. No other problems . In service. CUSTOMER TO CHECK OR REPLACE MAIN REGULATOR
Quakertown, PA 18951
Service C.
Service C. Checked in
Arrived on site and checked in with MOD. Customer complained Ice Machine unit evaporator coil frozen over and not making ice. found machine had been turned off. turned unit on and ran. unit made and dropped several batches of ice. spoke to Manitowoc tech support. tech support states, either the harvest flap had accidentally gotten pulled and threw off ice cycle causing coil to freeze. or unit lost water pressure due to water filters becoming temporarily clogged. will order new water filters and return to replace. if problem persists further diagnostic will be required at that time. 10/22/20 Arrived on site and checked in with MOD. customer states unit has worked properly since last visit. customer would like us to order water filters and return to perform pm. 10/23/20 Arrived on site and checked in with MOD. replaced all water filters and performed PM. ran and tested. unit working properly at this time.
Quakertown, PA 18951
Service C.
Service C. Checked in
The manager said he wanted the Prep Table coil defrosted and the evaporator hung back in place. Disassembled and defrosted the frozen evaporator coil. The evaporator was hanging by its tubing. Remounted tge coil back in place. If the coil continues to freeze up the customer should replace the temperature probes. Sprayed condenser with Nu calgone coil cleaner. Unit up and running.
Quakertown, PA 18951
Service C.
Service C. Checked in
checked bottom Vulcan convection oven. fan not shutting off with door opened. cannot shut oven down due to customer cooking. only have this oven right now with top oven down. also, left door handle broken. must replaced as a set. this original handle is no longer available. Will obtain necessary parts, return and replace. QWP authorized by Thane Gehret. 6/12/19 arrived on site to repair bottom Vulcan Hart convection oven. proceeded and replaced both door handles and door micro switch. brought oven into operation. customer mentioned that they were having trouble with oven heating prior. checked and found power level potentiometer going bad. disconnected plug on temperature control board for power level. customer said that they always leave the power level on 10 all the time. customer does not want this feature repair at this time. brought oven into operation and checked door switch operation okay. with door open, fan now shuts down. oven heating fine. oven in service.
Quakertown, PA 18951
Service C.
Service C. Checked in
Took measurements and pictures of door on Walk-In Cooler to send to fabricators to see about getting a ramp fabricated. Customer also wants handle ordered. CHG w38 series (Frank door) 1/25/19 Drilled holes in tiled floor and installed anchors and fastened down ramp. Also replaced door latch.
Quakertown, PA 18951
Service C.
Service C. Checked in
Found In addition to bad fan motors and gasket Reach-In Freezer unit is low charge with leak in evaporator. Will Quote repairs.
Quakertown, PA 18951
Service C.
Service C. Checked in
Checked top toaster and it powers up and heats but no cooling fans and no power to them from the motor board. Conveyer Motor is working. Pulled the toaster and removed the bottom and found the wires melted and shorted causing damage to the board. Need a conveyor/fan board and wire kit. I'd part from Benard in service at AJ Antunes . Will order and return. not in service. Order QWP (expedited freight) per James M. 1/4/19 Pulled top muffin toaster to an area to work on it. Disassemble and removed the shorted wires and installed the new wire kit per instructions . removed the old damaged motor/fan control board and installed new board. Zip tie wires in place and moved toaster back in place. 214 vac to toaster. Powered on and unit now heats and fans are now working. Conveyor working. Allow to reach set temps and test . Unit is at temp and is okay. Muffins are toasted properly . No errors. In service .
Quakertown, PA 18951
Service C.
Service C. Checked in
Opened up left Coffee Machine unit and is limed up. Added scale clean to it and allowed to escape for recommended time 30z40 minutes, drained out and cleaned what's left on the bottom of the tank. Cleaned probes and refill. Service light was on and had to reset the unit. Now it heats and brews properly. Levels okay, in service.
Quakertown, PA 18951
Service C.
Service C. Checked in
Checked out unit and found that pilot tube coming of valve have a big hole in it. causing flames to shoot out front panel. pilot tube and pilot are all one piece. Don't have anything like it on truck stock. Checked for part # and Franklin has been out of business for years. Will try and locate a retro kit for pilot assembly. Told customer situation. will let him (Steve) know when and if we can find retro kit. Turned off gas to 6 burner and flat top due to gas leaking out of pilot tube hole.
Quakertown, PA 18951
Service C.
Service C. Checked in
Checked out Bunn coffee unit, everything is working properly. Cleaned out tank and all probes. Unit filled and heated. Ran a lot of coffee, no leaks, everything good. unit in Service.
Quakertown, PA 18951
Service C.
Service C. Checked in
Found frypot leaks. Grease caught fire. Some wiring needs to be repaired and frypot needs to be replaced. Unit has a filter system
Quakertown, PA 18951

Planned Maintenance

A planned maintenance agreement can keep your equipment running longer than the factory warranty. Reduce cost, downtime and have your equipment running at top performance when you need it most.

We Do It Right The 1st Time!

See what our customers think about our service!

Great service Very courteous polite and knowledgeable The Gardens At Stroud Stroudsburg
Super Guys! The K & D Team of repairman are super!. always courteous, friendly and get the job done right! Answer my questions and never a surprise cost. Dunmore Health Care Center Dunmore
Maintenance Supervisor Shawn is a good Devoted Service Tech from your Altoona Offfice Steve Long is always a great help when i call him Mount Union School District Mount Union
Read More