Reading PA Commercial Refrigeration

K&D Factory Service has been providing factory authorized kitchen equipment parts and service to the businesses of Reading, PA and the surrounding areas since 1945!

How often should commercial refrigerators be serviced near Reading, PA

Commercial refrigerators should be serviced at least twice a year, preferably once before the summer season and again before the winter season. However, the frequency of servicing may depend on several factors such as the age of the equipment, usage patterns, and manufacturer's recommendations. Regular servicing can help identify and address potential issues before they become major problems, extend the lifespan of the equipment, and improve energy efficiency, which can save on energy costs. A professional refrigeration technician can perform routine maintenance tasks such as cleaning coils, checking refrigerant levels, and inspecting the system for leaks or other issues.

Why is my commercial refrigerator not blowing cold air near Reading, PA?

There are several reasons why a commercial refrigerator may not be blowing cold air:

  • Dirty coils or condenser: Dirt and debris on the coils can reduce the efficiency of the refrigeration system, causing it to work harder to maintain the temperature.
  • Low refrigerant levels: If the refrigerant level is low, the refrigeration system will not be able to cool the air properly.
  • Damaged or malfunctioning components: Components such as the compressor or thermostat can malfunction, causing the system to stop blowing cold air.
  • Poor ventilation: A lack of proper ventilation can prevent air from circulating properly, which can affect cooling efficiency.

It's recommended to call a professional refrigeration technician to diagnose and repair the issue to avoid further damage to the system.

Why is my commercial gas oven not heating up near Reading, PA?

A commercial gas oven may not heat up if the pilot light is out, the gas supply is disrupted, the thermostat is malfunctioning, or the igniter is faulty. It's recommended to have a professional technician inspect and repair the issue to avoid further damage to the oven.

Read our reviews and find out why your colleagues call us when they need OEM parts and equipment or refrigeration repair services in Reading, PA.

Recent Jobs and Reviews in Reading, PA

Rated 5.0 out of 5 stars based on 2 customer reviews

Job Locations and Reviews

Ashley B.
Ashley B. Checked in
Commercial Kitchen Appliance Repair: Responding to concerns about inaccurate thermostat control in a tilt skillet, I executed a precise calibration. This meticulous service guarantees consistent and precise cooking temperatures.
Reading, PA 19602
Ashley B.
Ashley B. Checked in
Comprehensive Commercial Kitchen Equipment Maintenance Service. I provided a full-service maintenance package covering all aspects of the client's kitchen equipment. My first step was thoroughly cleaning the condenser coils in the refrigeration units to ensure peak performance. Then, I meticulously inspected and maintained hinges, door gaskets, and seals on ovens and refrigerators to prevent heat or air leakage, thus extending the life of the appliances. Additionally, I replaced filters on all kitchen equipment, ensuring they operated at maximum efficiency. My service was tailored to the client's needs, guaranteeing well-maintained equipment for seamless operations.
Reading, PA 19602
Ashley B.
Ashley B. Checked in
Convection Oven Repairs: Our expert technicians swiftly addressed and repaired a malfunction in the convection oven. Subsequent to the repair, a meticulous performance assessment was conducted to ensure not only the restoration of optimal functionality but also to guarantee precise and even baking temperatures. This thorough evaluation aimed at achieving and maintaining consistent culinary excellence in the oven's performance.
Reading, PA 19602
Mark B.
Mark B. Checked in
Arrived on, 09/26/23- Tom-Found a all of ice on right side of evaporator on txv side ,I melted ice with water, I checked all operation including superheat and all are good unit is working properly at this time
Reading, PA 19607
Mark B.
Mark B. Checked in
Arrived on, 08/29/23- Tom- Found unit controller in off mode and I can’t find any info on how to operate controller, all info on line is in Spanish and unit is made in Mexico, Matt is going to further investigate manufacture. Returned on, 09/12/23- Tom- Unit was working properly when I arrived, customer said Pepsi repaired unit, checked pressures and temperature and is working properly at this time.
Reading, PA 19611
Mark B.
Mark B. Checked in
Arrived on, 08/28/23- Kayden- On arrival found that right side of bin had ice covering bin switch so unit was showing full bin that why it wasn’t making ice. Moved the ice out of the way so bin switch wasn’t closed and watched unit drop a batch of ice. Unit is working properly
Reading, PA 19607
Ashley B.
Ashley B. Checked in
Commercial Deep Fryer Installation. A commercial establishment sought to enhance its menu with a new commercial deep fryer. We positioned the fryer, connected the gas line and electrical wiring, and calibrated the temperature controls. Rigorous tests ensured consistent frying results, and the kitchen staff received training in operation and maintenance.
Reading, PA 19602
Mark B.
Mark B. Checked in
Commercial Kitchen Equipment Installation Service near Oley St. When a commercial client contacted us for assistance with installing new pressure fryers in their establishment, we promptly responded to their request. Our team arrived with the new pressure fryers and skillfully installed them, adhering to the manufacturer's guidelines. Thorough testing was conducted to guarantee optimal performance. The client expressed enthusiasm and satisfaction with the addition of the new appliances in their establishment!
Reading, PA 19604
Mark B.
Mark B. Checked in
Commercial Kitchen Appliance Repair. Arrived at the location on 4/17/23 - the screen would lock up. Found an error stored fill failed I did check and found the filter screen fairly clogged .at the ionized water connector I did clean the screen filter and checked operation. I drained the unit and attempted a rinse. The unit did complete a rinse ok. The unit is ready to use. Instructed the customer to run a full wash cycle and let us know if they need further assistance.
Reading, PA 19605
Daniel  D.
Daniel D. Checked in
Commercial refrigerator is experiencing temperature fluctuations and not maintaining the correct temperature. Checked the thermostated and calibrated. Issue is resolved
Reading, PA 19602
Mark B.
Mark B. Checked in
Arrived at location on 1/3/23 - Found unit off on clogged drain. Shut unit off and opened panel. Found no water around screws. Reset and turned on. Unit started to make ice. Unit made ice for 1 hr no problem. Checked amp draw and operation of ice machine. Seems to be in working order but would recommend a cleaning. They did not want at this time. Mounted wires to side of frame to prevent from going off on clogged drain. Unit is in operation at this time.
Reading, PA 19606
Mark B.
Mark B. Checked in
Arrived at Location on 8/17/22 - stated one of the combis is leaking when they turn both on to steam mode. Checked over, found top combi leaking at rear. Found hose going from solenoid to cavity has a hole in it. Remove covers to access. Remove hose and install new section of hose. Reassemble, test, no further leaks. Ok for use.
Reading, PA 19609
Mark B.
Mark B. Checked in
Arrived at location on 6/22/22 - Inspected unit. Found voltage to smoker element but no amp draw. Found cavity element also in need of replacement. Error 30 error is under temp for more than 90 min. Button overlay also broken and in need of replacement. Customer would like repairs to be scheduled for a Monday or Wednesday. Call and schedule when parts arrive. Returned to location on 6/29/22 - Unit not in use upon arrival unit needs new element,heat cable and overlay. Dismantle all panel dismantle old smoke heater. Dismantle insulation. Dismantle old heat cable. Dismantle old overlay. Install new smoke heat element, old heat cable and overlay. Test unit and observed unit operational.
Reading, PA 19605
Mark B.
Mark B. Checked in
Arrived at location on 6/17/22 - Found error f3 magnitron current error. Check found magnetrons slow to ramp up to full amp draw. Found magnetrons clogged with dirt and overheated found capicators weak and diodes were bad. I did replace the mags diode capicators and cleaned up the cooling fan and main fan motor area and cook chamber. I checked operation. Magnetrons now ramping up, correctly. I did erase the error logged. Unit is working as it should and ready to use.
Reading, PA 19605
Mark B.
Mark B. Checked in
Arrived at location on 5/19/22 - Grease trap has a hole in it. We will try to find a replacement unit. Customer wants a plastic unit if possible. Will need 2 =2.5 inch fern o couplers and a 3 by 2.5 inch coupler. Will call customer with part availability and schedule. I did put the vent pipe back together that had come apart . We will return did Epoxy the hole. Returned to location on 5/26/22 - Disconnected old grease trap. Set new grease trap in place. Cut up sink line to adapt new plumbing to new grease trap. Cut away outlet side plumbing. Run new plumbing from outlet of grease trap to drain line. Secure all drain lines and seal. Test, no leaks. Ok for use.
Reading, PA 19601
Mark B.
Mark B. Checked in
Arrived at location on 3/2/22 - Found holding cabinet temperature control knob I will obtain parts and return customer requested 3 pc. Returned to location on 3/11/22 - Installed new knob and set temp on the holding cabinet I checked ops. ok ready to use.
Reading, PA 19609
Mark B.
Mark B. Checked in
Arrived at location on 2/4/22 - Inspected unit #18. Found ground on plug to be broken off. Replaced plug. Tested unit ok for use.
Reading, PA 19604
Mark B.
Mark B. Checked in
Arrived at location on 1/10/22 - Found care pump is bad pulsing when running causing error. I will obtain parts and return . Returned to location on 1/14/22 - Replaced the care pump and started a light clean cycle. checked ops. Ok ready to use.
Reading, PA 19606
Mark B.
Mark B. Checked in
Arrived at location on 10/28/21 - Found start switch has come apart I will obtain parts and return. Returned to location on 11/1/21 - Replaced the start switch assy. I checked ops. Ok ready to use.
Reading, PA 19606
Mark B.
Mark B. Checked in
Arrived at location on 7/9/21 - Replaced torn door gaskets on both doors. I also noticed water dripping from the evaporator so I blew out the drain line and also found ice on the back of the evaporator. I removed the ice and checked pressures and they were a little low. The suction valve core was leaking so I replaced it and the flare cap. I added refrigerant and the unit is now cooling and draining properly.
Reading, PA 19601
Mark B.
Mark B. Checked in
Arrived at location on 6/14/21 Both units need gear, blade, blade shims and blade mount. Will obtain replacements and return. Returned to location on 6/25/21 Installed replacement blade, holder and shims. Tested unit ok for use. Second unit being taken to shop to repair cross thread.
Reading, PA 19604
Mark B.
Mark B. Checked in
Arrived at location on 6/11/21 and found blower switch block broken. Replaced with new. While in control box I noticed conveyor switch in poor condition. I also replaced that switch block. Tested heated ok for use
Reading, PA 19606
Libby D.
Libby D. Checked in
DISH ROOM SINK - 4/14/2021 - Addison Horning - arrived, stated hose to left of booster heater is leaking. checked and found leaking at faucet area around vacuum breaker. Will order parts and return, 4/21/2021 - Mike A - arrived on site and installed replacement faucet. tested unit ok for use. no leaks
Reading, PA 19606
Service C.
Service C. Checked in
arrived on site and installed BLO Oven replacement gas line to unit. tested unit OK for use
Reading, PA 19606
Service C.
Service C. Checked in
Arrived, stated Oven unit will cut out, not heating properly. no ignition light will stay on (ignition failure) unit is heating and operating now. removed covers. checked components. unit is sparking every time. 2 micro amps on flame sensor. gas pressure low at 2.5 inches. adjust up to 3.5 inches per manual. now have 3.5 micro amps on flame sensor. allow unit to heat and cycle several times. is operating well. reassemble unit. after reassembled, unit went into ignition failure. heat failure light would stay on, could heat unit sparking. removed covers again, cycled power, unit sparks but not lighting. no gas pressure to manifold. have voltage to gas valve. bad gas valve. customer also stated timer is not working. found buzzer will sound when timer is done but timer does not time down. bad timer, will order gas valve and timer. 9/4/20 Arrived on site and installed replacement gas valve and timer. tested unit and had proper functions. unit OK for use.
Reading, PA 19601
Review
great service
Enersys - Reading, PA 19605
Response from K&D Factory Service Inc.:

Thank you for sharing your kind words with us. It means the world to us and to our entire team!

Review
quick, prompt service at a decent price
Fairlane - Reading, PA 19606
Response from K&D Factory Service Inc.:

Thank you so much for this 5-star review. We really appreciate you being a customer and helping to share the word about us. We’re here for you anytime.

Planned Maintenance

A planned maintenance agreement can keep your equipment running longer than the factory warranty. Reduce cost, downtime and have your equipment running at top performance when you need it most.

We Do It Right The 1st Time!

See what our customers think about our service!

Great service Very courteous polite and knowledgeable The Gardens At Stroud Stroudsburg
Super Guys! The K & D Team of repairman are super!. always courteous, friendly and get the job done right! Answer my questions and never a surprise cost. Dunmore Health Care Center Dunmore
Maintenance Supervisor Shawn is a good Devoted Service Tech from your Altoona Offfice Steve Long is always a great help when i call him Mount Union School District Mount Union
Read More