Checked over Blended Ice Machine unit. found display blank with a line through the center. upon checking found all connections okay. will need to order display. 9/27/19 Replaced display and preformed update and got new menu emailed and uploaded. tested unit and found will need calibration. found customers scale did not work and they will calibrate it when they get scale working. unit functional at this time.

Near N Susquehanna Trail, Selinsgrove, PA 17870
Service C.

Service C.

Found Grill unit not heating when switch is turned on. Looked over unit found wire was pulled out of wire nut attached wire and taped wire nuts so wires wont come out again. Turned on and found unit to heat, let unit heat. Unit is operating correctly at this time.

Near N Susquehanna Trail, Selinsgrove, PA 17870
Service C.

Service C.

I checked over the Griddle unit and found multiple wires burnt, right heat selector switch bad, left stat bad and left terminal block needs replaced. The customer has the terminal block but we will need to order other parts and return to repair. All wires for the bottom terminal on left terminal block are zip ties together. The power is off to the unit at this time and I called the manufacturer for part numbers. 7/5/19 Installed parts tested unit, found okay, unit is operating correctly at this time.

Near Old Colony Rd, Selinsgrove, PA 17870
Service C.

Service C.

Bunn Coffee Machine - took the line apart, cut out the bad part of the hose and replaced the the clamp. Then leak checked fitting and everything looked good. The unit is working fine at this time.

Near S Market St, Selinsgrove, PA 17870
Service C.

Service C.

Found GRM Dispenser unit with dirty condenser cell. Cleaned coil, energized and checked operation. Found condenser fan motor locked up. Will need fan motor replaced. 2-1-19 Removed failed condenser fan and replaced. Energized unit and checked operation. Unit operating normally at this time. **Travel Charges billed on wo# 174680**

Near 11, Selinsgrove, PA 17870
Service C.

Service C.

Found microwave oven mags not working on unit due to high limit burnt on top mag. Replaced high limit on mag and tested unit, found to be working okay at this time. 10-23-18 Dropped off repaired microwave, when in area.

Near S Market St, Selinsgrove, PA 17870
Service C.

Service C.

There was power to the Dishwasher unit but nothing would come on. I found one of the small fuses was blown so I replaced it and when the unit went to drain I heard a pop. I disconnected the sink next to the unit so I could access the back of the unit. I found the vacuum break leaked and caused a dead short in the drain pump. I tested the other components and they all appeared to be working okay. We will need to order parts and return to repair the unit. I spoke to Jason at Insinger and he gave me the part numbers needed. The staff said I could leave the sink out and put it back in when we return. 7-24-18 - Removed the old drain pump, vacuum break, fittings, burnt terminals and pump timer and installed new. Then hooked up sink that is located next to the unit so I could turn the water back on. Then checked operation on the unit and it was running fine so I finished installing the sink. I checked for leaks and everything looked good. The unit is running fine at this time.

Near N Old Trail, Selinsgrove, PA 17870
Service C.

Service C.

Found ice bin full. Ran unit through cycles, found working okay. Found unit full of scale, thickness sensor and water level sensor need replaced, unit will also need cleaned, bridge is too thick. 1/16/18 Found unit not running. Inspected unit found ice curtain stuck open and unit stuck in full bin status. Repaired ice curtain, removed ice thickness sensor, water level sensor and replaced with new parts. Energized and checked operation. Set bridge thickness. Unit operating normally at this time harvesting every 12 min. 30 sec. Spoke with manager would like cleaning scheduled. Also found head unit support grace installed incorrectly. Tried to relocate but screw is stripped will need drilled out when machine is empty.

Near Nina Dr, Selinsgrove, PA 17870
Service C.

Service C.

Found unit # 3, only heating back side element, checked switch, found when switch is bumped it would occasionally heat both elements. Needs new switch. While checking voltage trough element, a microwave door was shut causing bracket to short out on element. Fount element will now not heat at all. and rear element is only 50%. Needs elements also. 1-5-18 Removed failed heating elements and installed two new elements and left extra for spare on site. Removed failed infinite switch and installed new switch, energized and checked operation. Found no power to front side elements . Found breaker bad and wiring burnt and bare inside conduit. Replaced breaker and rewired heating elements. energized unit all operations normal.

Near Susquehanna Valley Mall Dr, Selinsgrove, PA 17870
Service C.

Service C.

Found unit on. Replaced gas valves and knobs. Found gas leaking from valve and removed it, found 1st t-stat valve also needs replaced as well as flange and o ring. Will order and return. **travel/miles wo#131029

Near N Susquehanna Trail, Selinsgrove, PA 17870
Service C.

Service C.

Found unit on and in use. spoke with manager he showed me issues with grill found three right thermostats bad and need replaced also can not shut off the right two and always put out gas. will also need unit to be cleaned out cause it''s full of soot burners will need to be pulled out and cleaned as well recommended unit be shut down due to safety hazard. possibly a fire hazard will submit a quote for repairs.

Near N Susquehanna Trail, Selinsgrove, PA 17870
Service C.

Service C.

Turned unit off, let cool. Adjusted springs in back as tight as possible, told customer they were very worn. Will order springs and shock and return to install. 1-3-17 Removed from line and let cool. Removed old springs and shocks and installed new. Unit okay at this time. **Travel Charges billed on WO#125838

Near N Susquehanna Trail, Selinsgrove, PA 17870
Service C.

Service C.

Found unit (GAR Broiler) with broken spring on valve, replaced valve and installed temporary knob on 3rd valve from left, for burner. Will obtain correct knob and return to replace. -- found unit on and working. Swapped out temporary knob with correct part. Unit is okay at this time.

Near Marketplace Blvd, Selinsgrove, PA 17870
Service C.

Service C.

Disconnected all equipment and moved to the hall. Moved :1 range, 2 reach in coolers, 1 dishwasher and 2 sinks. Will return to install units when floor is done, will need a few shark bites for installation of equipment. -- Put all equipment back into kitchen. Hooked up all gas electrical and plumbing. Checked to make sure all equipment was working properly. Found okay.

Near N Market St, Selinsgrove, PA 17870
Service C.

Service C.

found unit (filter system) with cracks in both front corners, took pictures. Will schedule time to weld on site or pick up to weld at shop. picked up filter pan to weld at shop. welded split corner on unit. Returned unit to customer. **Travel Charges billed on WO#110861

Near S Market St, Selinsgrove, PA 17870
Service C.

Service C.

Pitco fryer - found left arm in 2nd vat was down. Pulled back cover, found fuse blown and motor breaking apart. Will need motor. Closed up unit, working okay at this time. Gave customer quote

Near S Market St, Selinsgrove, PA 17870
Service Check-In ..

Service Check-In ..

KOLPAK WALK IN COOLER Tech - found unit running but holding 47*F box temp. Checked coil, found extremely dirty. Cleaned, checked operations, found unit with high superheat. Added 5 oz R404A refrigerant to obtain 20*F of superheat at compressor. All operations normal. Unit cycling at 34*F when finished.

Near N Susquehanna Trail, Selinsgrove, PA 17870
Service Check-In ..

Service Check-In ..

Pitco Charbroiler Model-TR-636-IG - Service-Performed 6-25-15 Steve L- found unit off. 2 knobs too tight to turn. Shut off gas, accessed valves. Tried to repair, got center knob loosened a bit. Right knob bad. Moved to left location. Customer wants extra on hand. Also found pilot tube bad, big hole. Adjusted gas to 4"wc, ok per manager. 7-10-15 Kyle B- removed gas from units. Removed bolts that hold pilot tube and replaced pilot tubes in each unit. Replaced 3 valves (1,2,4 positions) on left unit and replaced 1 valve (position 6) on right unit. Both pilots lit all the way across and all valves easily turned burners on. Left extra 2 valves with manager, unit ready to use.