K&D Factory Service Inc. bas been bringing OEM commercial cooking parts and service to restaurants and commercial kitchens of Gettysburg, PA and the surrounding areas since 1945!
Read our reviews and find out why your colleagues consider us to be their nearby commercial cooking supply company in Gettysburg, PA.
Commercial kitchen equipment is usually built to endure heavy use. For your foodservice business to function effectively, your equipment must be in good working order. Here are a few tips:
- Review your owner’s manuals: it is essential to become acquainted with the restaurant equipment by reading the owner's handbook to learn how to use and maintain your equipment.
- Make repairs right away: after years of usage, parts and components deteriorate. When you detect a damaged or noisy component, it is critical that you have it fixed by a skilled expert.
- Keep your equipment clean and sterilized: this simple tip can help to avoid the accumulation of food particles, dirt, rust and debris, which can lead to equipment failure.
- Have regular professional maintenance scheduled: this aids not only in safety precautions, but also in ensuring that your kitchen equipment is operating at optimum efficiency.
K&D Factory Service specializes in commercial kitchen equipment service of all kinds. Call us for all your cooking equipment maintenance needs.
Call us right away! We understand how important reliable restaurant equipment is to the success of your business. We offer all of the commercial kitchen repair, maintenance and replacement services you require. Our skilled technicians are experienced and well-equipped to repair a wide range of culinary equipment from leading manufacturers.
Commercial ovens come in a variety of sizes and forms, but there are three basic concerns that can arise in nearly any kitchen.
- The oven won't heat up or cool down. In such circumstances, changing your industrial oven thermostat may be the only option.
- The pilot light will not ignite. The problem is most likely a faulty thermocouple. If a replacement thermocouple causes the same problem, the safety valve might be to blame. Only a professional technician can make that determination, so if this is your oven problem, contact us at once.
The food comes out fried or frozen. An incorrectly fitted thermostat is most likely the source of this commercial oven hazard. In some situations, a replacement thermostat may be required.
Local Reviews
for Gettysburg, PA
Our Reviews by City
Took some time but the end result was great!
John - Gettysburg, PA 17325
GettysburgPA17325 39.8375-77.2375




courteous and knowledgeable staff
ARAMARK-Gettysburg - Gettysburg, PA 17325
the guys are always helpful
GettysburgPA17325 39.8125-77.225



Service techs are always professional
SpiriTrust - Gettysburg, PA 17325
GettysburgPA17325 39.8525-77.215




usually quick service - good people over all good experience
Gettysburg college Dining service - Gettysburg, PA 17325
today service repair work is expensive and I understand the costs. I would like to see a discount or wave travel $$ after we have 'X' amount of service calls. something like (unfortunate) frequent flyer program.
GettysburgPA17325 39.8375-77.2375



poor tech knolwledge of equipment
AraMark-Gettysburg - Gettysburg, PA 17325
Ice maker having issues. Tech complained of poor water PSI. GF staff checked water source finding no isues. After discussing issue with tech, he deciced to relpace PSI gauge. new gauge showed great water PSI. too many reoccuring repairs for same issues
GettysburgPA17325 39.8125-77.225



Mark B.
Arrived at location on 3/18/22 - Tighten sight glass. Was loose. Completed. Water filter leaking needs quote. Steam valve at kettle leaking again. Wants better valve.
Mark B.
Arrived at location on 10/19/21 - Replaced thermopile in right fryer and center fryer. Set both to 500 mv. Right fryer at 185mv with burner on, center fryer at 235mv with burner on. Both working at this time. Completed.
Mark B.
Arrived at location on 10/4/21 - Found condenser fan motor bad, and both evaporator fan motors bad. I replaced all motors from truck stock and waited for unit to come down to temperature and is working properly at this time.
Mark B.
Arrived at location on 8/7/21 - Found fryer totally down, dropped panel and found that someone had attempted to jump out switch. Rewired correctly and unit power on. Turned on fryers and hood came on. Allowed vats to come up to temp. Ok for use. Will return with replacement power switch. Returned to location on 8/11/21 - Pulled fryer out, replaced drain pan switch. Verified operation, working now. Pushed fryer back in. Replaced power switch, new wire ends female crimp. Rewired to factory diagram. Verified hood on and fryers. Labeled wires also. Completed.
Mark B.
Arrived at location on 8/5/21 - Pulled burner to check orifice. Found mouse in burner tube. Pulled mouse out, cleaned burner. Lit up fine now. Dave wants new knob for valve. Unit is less then 15 years old. Working now. Just need to drop new knob off. Returned on 8/9/21 - Drop off knob Dave wanted ordered for the steam table I just fixed. Completed.
Mark B.
Arrived at location on 7/30/21 - Unit slow dial almost all way up. Checked motor grease coming out, shaft is going bad. Also will replace diode. Will order parts. Returned to location on 8/4/21 - Replaced drive speed motor and diode. Turned on, told David and the lady cook to try it. Needs product ran thru to see if they happy with it. Completed.
Libby D.
PITCO FRYER (3rd from left) - 04/02/21-James T- Adjusted Ingnitor. Was bent up and touching the shield. Also found flame roll out switch tripped. Reset it. Has self cleaning burners. May have tripped on miss fire due to ignitor not sparking right. Working now. Heated to 370. Completed.
Service C.
Arrived. Convection Oven unit was on, checked and found it wasn't proving flame everything. Found low microamps on flame rod. Installed new and tested, now has .25 micro amps. Watched unit cycle and holds temp. Ok for use at this time.
Service C.
Found VHL Steamer fill valve hose leaking. Had to go get one. Put on, brought up to temp. Tested ok, no leaks. Operation ok at this time.
Service C.
Found Prep Table condensing fan motor had a bad connection, Fixed and system started operating, Checked refrigerant level and found that system was low on charge, Used electronic leak tester and did not get any hits, Used soap and still could not find the leak. System is operating properly at this time but cannot guarantee for how long.
Service C.
Steamer In use when got here. She said working great this morning. Drained it. Pulled hi limit, cleaned. Pulled bottom hose off delime port, tried to stick rod back thru, feels as though the steam generator is limed up and some of hose fittings. Could not get water level probes out to check or clean. Recommend getting new tank gasket and water level probes, to be able to take unit apart and get back in use same day. May need major delime if tank solid with lime. Unit did over fill one time during refill. Water was coming out top of steam generator. Need to quote repairs.
Service C.
Top Middleby Oven: found fuse blown replaced fuse right motor bad will give estimate to Chad. 6/15/20 Disassembled oven. Had to cut blower shaft, Very hard to cut. Could not get heat Slinger off, Set screw stripped and cracked. Will have to order new heat Slinger. Left belt off. But put oven back together so no parts get lost. Clean up area. 06/23/20 Replaced right side motor, heat Slinger, and blower wheel. Re-assembled unit and fixed belt. Started up tested. Doug said okay. Completed.
Service C.
Performed pm on 4 Rational ovens units in main kitchen. Checked for scale in boilers, were none. Checked for leaks, were none. Checked all functions, operation ok. Advised will need to replace igniter. Customer will call if wants parts ordered. Software is up to date. 1/10/2020 Returned to finish pm on 2 units. Also updated software, tested ok.
Service C.
Walk-in cooler was temping at 44 degrees upon arrival. took down Slimline cover and found inside evaporator coils were extremely Dusty. Remove power to the fans and brushed out heavy dust and blue the rest out with nitrogen. turn the unit back on, had bubbles in sight glass. charge was a little low. Added 8 oz of R22 refrigerant and checked for leaks. No leaks detected at this time. I adjusted the thermostat to turn off at 34 degrees and on at 39 degrees. Recommended to general manager that all three walk-in units should be heavily cleaned. Please provide quote for General Manager to provide preventive maintenance on the walk-in coolers and freezer.
Service C.
After inspecting and removing burners from Fryer-Electric, found that fire wall was damaged and falling apart. Spoke with Gary and he is going to replace fryer due to age of unit. Unit is from 1998.
Service C.
Replaced Bun/Toast Selector switch, called factory, got wiring diagram, verified mounting position and verified wiring correct. Ran product through, tested both switch positions. okay now. Completed. **Travel credit on WO# 186355
Service C.
Found Blended Ice Machine left motor locked up and door broke, will order. 6-11-19 Arrived at location. Replaced left motor. Tested motor for proper function. Replaced both doors due to damage. No further problems.
Service C.
Customer requested Ice Machine bin to be emptied and cleaned. Emptied bin. Cleaned and sanitized bin and ice machine. Chemically cleaned all washable parts. Blew out condenser coil with nitrogen. Unit made 3 batches of ice. ice thickness is good. unit is working properly at this time.
Service C.
Combi Oven fuse blown for control, replaced fuse, found cds sensor leaking on pump, disconnected pump so they can use till I get a pump and sensor. 3-7-19 Installed pump, water sensor and fuse. ran rinse, tested okay.
Service C.
Removed and replaced Griddle left pilot assembly, unit is operating properly at this time.
Service C.
Checked all units in back cooking line, cleaned condenser and checked temps. Drawer case, had to use cleaner. Will return to finish, 1/03/2019 Finished checking equipment, blew out condenser and cleaned the ones that needed it with cleaner. Checked for proper temps.
Service C.
Stop button on Disposer station needs replaced, cover is missing and loose. 11/14/18 Removed and replaced stop button assembly and checked operation. Unit is cycling properly at this time.
Service C.
Found bad switch on Refrigerated Drawer Unit, replaced it, unit ran and pulled temp.
Service C.
Installed door switch on SBR Range, tested okay.
Service C.
Tested, found door leaking at bottom, found bottom right corner folded in. Will order new and return. Travel & Miles on work order 152159 3/12/18 Installed new door gasket, had to adjust door, found door drip tray clogged. Unclogged, tested unit, now okay.