problem is with the bottom right oven . power on and it shows service 37 and a service 36 which are pressure sensor issues . Turned on data window and checked the pressure sensor and have no voltage reading. Checked and have no power to the connection on the pressure sensor. Checked at the board behind the front panel and the connector for the pressure sensor was off the board. Put it back on and its tight . Run unit and now have the 12vdc at the pressure switch. In steam and combi modes the is 2.7v on the data window. Unit now running and no error codes . Cleared the error code list and unit starts up and no codes show up. In service

Near Fritch Dr, Bethlehem, PA 18020
Service C.

Service C.

Removed old unit and set new Follet Ice Machine in place. Hooked up water and drain lines and made sure there were no leaks. Machine is making ice.

Near Wyandotte St, Bethlehem, PA 18015
Service C.

Service C.

Checked the left Combi Oven unit and all pumps and valves work. Error 25 is a clean jet error but could be caused by no water or clean jet pump or misaligned blower shield. Could also be the quenching valve. Checked all and all work. Door gasket okay. Clean jet pump moves water properly. Ran a rinse without tablets and it completes the cycle. Did a interim clean cycle and okay. No problem found. Possibly of something caught in the clean jet pump. Unit is working at this time. In service .

Near Main St, Bethlehem, PA 18018
Service C.

Service C.

Waited until product is done and shut off Gas Fryer unit. Pulled forward and removed the back and side cover . Removed the valve and switch the fittings too the new valve . Install back in unit and close up. Unit calls for filtering and customer did add new oil. Heat to set point and customer has chicken in it. Allow to cook and time down and now valve opens and relieves the pressure. The chicken temps out ok. Back in service

Near Freemansburg Ave, Bethlehem, PA 18020
Service C.

Service C.

Looked over wiring. The VHL Range middle thermostat wire was corroded and broke off of terminal. Also found another terminal that was corroded. Cut off that terminal. Repaired both wires and installed new terminals. Turn on. 28 amps on each. All heating okay. Back in service.

Near Avenue C, Bethlehem, PA 18017
Service C.

Service C.

Top oven is off. Power on and left blower comes on but not the right blower as viewed from the front. Open control panel and the right safety switch is wore away and not closing fully. Also the 15 amp breaker to the left of the safety switch was tripped . Reset and now motors run and unit heats. Taped on a spacer to the panel so safety switch closes fully and unit runs. Under 1.5 amp at circuit 15 amp breaker. Will obtain a door safety switch and a circuit breaker and return. In service. 4/3/19 Top oven on but okay to do job. Cut power and replaced the 15 amp circuit breaker left of the safety switch and the safety switch. Also removed motor guards and lubed all 4 bearings and cleaned the motor vents of dust . Power on and restarted unit and it heats to set point and cycles maintaining set point. Bearings quiet . Back in service .

Near Easton Ave, Bethlehem, PA 18018
Service C.

Service C.

Checked Broiler unit, t couple had 31mv, pilot good and strong. Flame on pilot didn't go down when turning on burners. Replaced pilot safety head. Tested for leaks, none present. Lit pilot and turned both burners on, let heat on hi for 30 minutes. Unit ran fine, got every hot on top set to hi. Unit operational ,job complete.

Near Woodlawn Ave, Bethlehem, PA 18018
Service C.

Service C.

Arrived on site to check lower Hatco heatlamp, accessed element connections and found far connection and wire burnt. Wire broken off closest end connection, checked element - okay. Pulled new wire to far end of element, reterminated wire and connected to element. Replaced short end of wire and closest end and reterminated. Checked voltage at 241 volts, brought heatlamp into operation and checked amp draw of element at 5.5 amps, heatlamp in service.

Near Linden St, Bethlehem, PA 18018
Service C.

Service C.

Checked Steamer unit, found probes stripped, conv fan motor has 120v going to it but not spinning. Also hi limit was tripped, had to remove side panel to pull and reset because when they put steamer on shelf they installed too far back and not over reset hole. Will try to drill hole so they can reset. Fired unit and let it steam for 15 minutes, seemed okay but will order limit and check gas pressure on return trip. 11/26/18 Pulled out c/I'd and charbroiler to get behind steamer. Removed old hi limit, Probes, blower wheel and can. Installed new. Reassembled. Turned on. Jason from Maintenance said the steamer got so hot it melted the plastic envelope for the schematics. Let heat and observe. Came to steam. Let run for 30 minutes. No failures. Cycled to maintain steam. 4" wc. Showed Jason. He okayed repair. Back in service.

Near Saucon Valley Rd, Bethlehem, PA 18015
Service C.

Service C.

Mike gave me a picture showing how the wiring should be on Dishwasher soap dispenser. Did not see any wires not being used. Spoke to Albert at Champion. Sent him pictures and he said that the wiring is okay on the machine. Had me check power on the secondary side of the transformer. 120v. Said to go from X2 to any point on the neutral terminal. Have 120v. Checked from neutral to the input side of Line Power on the fuse block. Have 0v. He checked into it and said it''s wired differently. Now the power comes from the thermostat after the machine is filled. Turned on. Once filled there was 120v at the Line power in and out. Machine is working properly. Chemical company needs to return to hook up the pumps. The machine must be filled before power is supplied to the pumps. Albert said this is non warranty. There needs to be a power quick disconnect at the machine. Currently there is none.

Near Columbia St, Bethlehem, PA 18015
Service C.

Service C.

Combi Oven Unit in use on arrival. In steam mode. After a few minutes E20 appeared. This is a meat probe error. Somebody had started a cycle with the meat probe option but there is no probe attached to the oven. This is why the error was occurring. Without a probe the user must use the temp and time only. Set it to time. Checked gas pressure. 5.5" wc natural gas. Ran it in all modes, steam, combi, hot air and retherm. No other errors appeared and no re-occurrence of the E20 error. Spoke to one of the cooks who uses the oven and showed him the E20 error and he said that was the error that was appearing. Spoke to Luis who is the kitchen manager and he said it was an ignition failure. Checked igniter and flame sensor. Cleaned. All connections, secure. No damaged wires. Ran for over an hour and no failure. Cannot duplicate ignition failure. Back in service. Customer will call if it happens again.

Near Freemansburg Ave, Bethlehem, PA 18020
Service C.

Service C.

Arrived at location and Toaster unit was on, conveyor did stop and unit sparked when moved. I checked, there was no broken or burnt wires. I tightened up all connections to make sure nothing was loose. Checked motor and motor is working, not getting hot, getting correct voltage 120v. Also I adjusted and tightened conveyor belt on unit...Tested unit and motor or conveyor belt haven't stopped, unit heats up to temp. Problem might be intermittent. I suggested to customer to change motor but customer said no as the old one still works. They will continue to use until motor fails.. unit in service

Near W Union Blvd, Bethlehem, PA 18018
Service C.

Service C.

Pulled front and left side panels of Fagor dishwasher, turned unit on, found drain line at drain pump leaking. Will obtain and return, is fitted hose at pump, unit down requires parts. 9/6/18 Installed new hose. Turned on. Ran several cycles. Drained. Filled back up and ran more cycles. Customer ran dishes. Came out okay. No other leaks detected. Wash temp at 150. Rinse at 180. Back in service.

Near Emery St, Bethlehem, PA 18015
Service C.

Service C.

Found Under Counter Refrigerator Unit running, left evaporator iced up. Unit is empty, unplugged to defrost overnight. Iced up due to high activity. Will order defrost timer to install. Ordered through Grainger. 6/27/18 Follow up - Wired in defrost timer to eliminate icing up issue. Was unplugged when arrived, started unit after installing timer temp dropped to 35F and cycled off. Timer enters defrost every 6 hrs for 25 minute duration.

Near Riverside Dr, Bethlehem, PA 18015
Service C.

Service C.

Found Unit low charge, service caps loose, no leak detected. Recharged unit. Unit cooling properly.

Near Linden St, Bethlehem, PA 18017
Service C.

Service C.

Found top door closes but Is hard to open. Have to push up hard or hit. handle to open the door. Screws on latch were loose ,tighten down but still hard to open . Close door and let heat to steam. okay. no steam loss at all. Door strike and latch look wore. will order new parts and return. 4/4/18 Follow up- Replaced door latch assembly and tested door latches and operates properly.

Near University Dr, Bethlehem, PA 18015
Service C.

Service C.

Checked unit, found #2 vat right side, crispy tender. return valve clogged. Tried to manually open return valve and poke out from inside tank with no success. Pulled rear panel to access return valve, pulled valve and attached lines, cleaned compacted crumbs out and cleared passway. Returned oil from pan to vat and did 2 full maint. filters unit operational. Job complete, not being filtered properly either not enough times per day or not cleaning pan or changing pad and pot in between.

Near Wyandotte St, Bethlehem, PA 18015
Service C.

Service C.

Found time manual switch bad on Cleveland steamer, also not steaming in time mode runs for 2 min then shuts down tries to remote with out success. will obtain twin parts and return. bottom cab down. 2/9/18 Installed parts unit for red in time mode and ran put in manual had power out to 60 min timer but nothing out. timer is bad will obtain part. and return. part number cle300150. top and bottom operational in time mode but bottom needs part. ** No charge per Service Manager 2/13/18 Installed part cle300150 60 min timer and tested unit operational job complete. ** Travel Charges billed on WO#150373

Near Spring St, Bethlehem, PA 18018
Service C.

Service C.

Customer had me check the griddle while on location. complains of loss of heat during busy times. Tested gas pressure and found it low @ 2.8 inches wc. Tried adjusting but couldn't get higher than 3.5 inches and it drops to 2.7 and never stays up . Put on a new regulator and adjusted for 4 inches wc. Gas pressure now higher but still goes down to 3.1 when middleby ovens call for heat but climbs back up . Customer should call the gas co to have building gas pressure checked. Flow is not good . unit is in better service now. in Service. ** Travel Charges billed on WO#150187

Near Easton Ave, Bethlehem, PA 18017
Service C.

Service C.

Installed new toggle switch on heat lamp. Turned on, now heating. Back in Service.

Near Main St, Bethlehem, PA 18018
Service C.

Service C.

Top unit. Found meat probe bad. Customer has aluminum foil around it where sensors are. Removed probe and installed new probe. Calibrate probe. Run unit and set meat probe to 200 and run in steam. Probe shuts off heat at 200. In service. Run a rinse w/o tabs to check clean jet system- also ok. No other problems.

Near Main St, Bethlehem, PA 18018
Service C.

Service C.

Adjusted door handle to pull in door tighter but now it pops open. Pulled off right side panel. Found pressure switch broke off of fitting. Need new. Left note on door saying not to use until we repair. 4/13/17 Installed new pressure switch. Turn on. Let heat to steam coming out of vent. Pressure switch has 216v. A little steam comes out of the vent but not a lot. Cleaned both check valves but still only a little steam. Need new check valves. Also - had it on hold mode and temp went to 212. Probe reading 3.8 mv @ 200F. Spoke to Steve @ Groen. Said to replace hold t-stat if probe reading is okay. Will obtain parts & return. QWP (expedited freight) ** No charge labor per Service Manager for 4/13/17 4/24/17 Installed new t-stat and check valves. Reassembled all. Turn on. Heats to steam. A little steam escapes the door. Adjusted handle the best I could. Set to 180 and put in hold mode. Held at 180F. Back in service.

Near Westgate Dr, Bethlehem, PA 18017
Service C.

Service C.

Reset button fell off motor due to damage to the button cap. Motor was replaced in January but damage voids the warranty. Will try to locate the old motor and remove reset switch. Will return. Found old motor and removed reset switch and cover 4/4/17. 4/6/17 Removed old broken button and installed another button from another pump which was inoperable. Now filter has suction and discharge. Back in service.

Near Main St, Bethlehem, PA 18018
Service C.

Service C.

Turned on and PROB is displayed and unit does not fill. This indicates a failed temp probe. Per Daryl @ F/M ohms reading should be around 730 ohms at room temp. Actual is 1040 ohms. Need new probe. Will obtain & return. 3/3/17 Installed new temp probe. Turn on. Fills with water. Heats to boiling. Back in service.

Near Sands Blvd, Bethlehem, PA 18015
Service C.

Service C.

Found door and rack switches completing. PLC has 24 v output to drive contactor , contactor failed. Ran to supply house and picked up replacement . Unit ran for 5 seconds then stopped. Contactor fuse is bad. Replaced fuse. Unit is running. 2/21/17 Follow up - replaced wash contactor with oem contactor and checked operation