K&D Factory Service Inc. provides service for commercial cooking equipment to the businesses of Bethlehem, PA and the surrounding areas since 1945.

Read our reviews and find out why your neighbors consider us to be their nearby source for factory authorized parts and service and commercial equipment supplies in Bethlehem, PA.

What do you do if your commercial ice machine stops making ice near Bethlehem, PA?

If your commercial ice machine stops making ice in Bethlehem, PA, you should: 

  • Check what the thermostat is set to. 
  • Check the power to your ice machine. 
  • Check the water supply to your ice machine. 

You should also check to see if your commercial ice machine is potentially clogged. If you check all of these things and your commercial ice machine is still not working, you should have a technician repair it. To get your commercial ice machine repaired, call us today.

Why is my commercial refrigerator not getting cold enough near Bethlehem, PA?

Your commercial refrigerator may not be getting cold enough in Bethlehem, PA because:

  • Your commercial refrigerator’s condenser coils are dirty. 
  • Your commercial refrigerator’s thermostat is broken. 
  • Your commercial refrigerator’s door doesn't seal properly.  

In some instances, your refrigerator may also be placed in a location that makes it difficult for the refrigerator to maintain a cool temperature. To find out more about getting your commercial refrigerator fixed, contact us today.

Who can I call when our commercial dishwasher is leaking near Bethlehem, PA?

If your commercial dishwasher is leaking in Bethlehem, PA, you can call K & D Factory Services. At K & D Factory Services, we specialize in a wide variety of commercial appliance services, ranging from repairs, maintenance and installation. If you need your commercial dishwasher repaired or replaced, we can help. To learn more about getting your commercial dishwasher repaired or replaced, give us a call today.

Local Reviews
for Bethlehem, PA

K&D Factory Service Inc. Rated 3.0 out of 5 stars based on 1 customer reviews


Map of Bethlehem, PA

Manager




Review of K&D Factory Service Inc.


Mark B.

Mark B.

Arrived at location on 9/2/21 - Checked in with Chef Pete. Checked over right side kettle next to Cleveland steamers. Turned on. Low Water light stays on. Checked sight glass. No water, filled jacket with distilled water, supplied by customer. Filled to half way level in the sight glass. Turned on. Set thermostat all the way up. As per instructions, let pressure get to 5 PSI and pulled on PRV pin to release air. Repeated 4 times. Put in cold water. Pressure dropped and came to 25" Hg. Filled with more cold water and turned on to high. The PRV valve release pin is broken. Chef Pete said to replace the valve. Will obtain. Water came to a rolling boil. Chef Pete verified. Will obtain PRV and return. Returned to location on 9/7/21 - Removed old PRV and installed new. Bled air. Cooled down kettle and it pulled a vacuum. Filled kettle with water and turned on. Heated. Water is boiling. Back in service.

Near Schoenersville Rd, Bethlehem, PA 18017
Mark B.

Mark B.

Arrived at location on 8/19/21 - Per Chef Sean replace the hose assy on the kettle. Will order and return. Returned to location on 8/26/21 - Arrived and customer allowed me in and made way to 3rd floor Removed the old filler hose assy and installed the new filler hose assy. Tighten down the whole faucet assy. Turn on the water and test. No leaks and filler assy works properly. In service.

Near Founders Way, Bethlehem, PA 18015
Mark B.

Mark B.

Arrived at location on 7/23/21 - put temp probe inside bottom oven. (Jason said it's the one) unit fired rite up came to 367 then dropped to 345 and came back on. After 30min. temp was less and variance was more. 325 to 330. Burner lit every time. changed controller and temp probe. Retested and temp and variance is good. Settled to 352. Had problem getting screws out for temp probe. Did remove them. Unit is operational job complete.

Near Saucon Valley Rd, Bethlehem, PA 18015
Mark B.

Mark B.

Arrived at location on 6/18/21 checked the bottom oven and the display comes on and can be set in a cook mode but the start button is not responding. This has been a continuous problem per customer. Encoder or display is acting up. Could not get ahold of Angelopo but no one answers the phone. Want part numbers for display and rinse pump then I took and used in the top oven to get it going for customer. Need parts. Will id and call for approval on repairs. Bottom not in service . Top is ok. Returned to location on 6/23/21 Installed new Rinse Aid Pump and control board(display) on bottom oven. Turned on and let preheat. Pressed Start and oven preheated to 500. Started a cycle and took video of operation. Back in service.

Near Wind Creek Blvd, Bethlehem, PA 18015
Mark B.

Mark B.

Arrived to location on 6/17/21 and spoke to manager. Opened panel on unit and checked dispenser connections. Had to disassemble front panel and remover dispenser from front panel. Dispenser connections to spouts were both clogged. cleaned each spout thoroughly and reassembled unit. Unit now works to specification. unit back in service.

Near Wood St, Bethlehem, PA 18018
Mark B.

Mark B.

Arrived at location on 6/17/21 and spoke to manager. Opened panel on unit and checked dispenser connections. Had to disassemble front panel and remover dispenser from front panel. Dispenser connections to spouts were both clogged. Cleaned each spout thoroughly and reassembled unit. Unit now works to specification. unit back in service.

Near Wood St, Bethlehem, PA 18018
Mark B.

Mark B.

Arrived at location on 6/12/21, Upon arrival noticed a 20inch fan blowing on high directly in burner compartments. Took pic, moved fan. Lit both oven pilots and set to 350. Came to temp and cycled. Cleaned air vent in regulator. Unit is operational job complete.

Near Riverside Drive, Bethlehem, PA 18015
Mark B.

Mark B.

Arrived at location on 6/2/21, to service tilt skillet. Checked elements for resistance. Getting about 60 ohms on each element. Inspected wires for shorts, found nothing inside the unit. Checked contactors for shorts, found nothing. Traced power plug and found l2 and l3 shorted out inside loom. Cut wires back, stripped and rewired plug. Checked tstat and capillary, they were okay. Need new bulbs for power light and heat indicator. Will obtain and return. Replaced the power switch and the 24 vac light and the temperature knob. Power on and unit heats up and have 12 amp heating. Tested the tilt switch and it shuts off the unit when tilted . Light now works. Back in service.

Near Wind Creek Blvd, Bethlehem, PA 18015
Mark B.

Mark B.

Arrived at location on 6/7/21 to check on double stacked pizza oven. Found compression nut broken for pilot. Cut off and replaced. Tightened down and lit pilot. It held and burners came on. Came to temp and went into by-pass. Unit is operational job complete.

Near Crawford Dr, Bethlehem, PA 18017
Service C.

Service C.

Arrived on site and checked in with MOD. customer complained walk in cooler not maintaining temperature. checked condenser and found condenser fan motor is bad. need to replace. will order and return to repair. further diagnostic will be required at that time. 10/7/20 Arrived on site and checked in with MOD. removed and replaced condenser fan motor. ran and tested unit. found system low of R-22 charge. charged system with R-22. ran and tested. unit working properly at this time.

Near Main St, Bethlehem, PA 18018
Service C.

Service C.

Found the Under Counter Refrigerator unit off. Turned on and tested. Found the compressor came on but the temperature in the box went up. One of the condenser fans did not work. There was no. heat being taken out of the box. Got a saddle valve and installed it. Found the refrigerant pressure at 0 PSI when on. Leak tested the system. My electronic detector only went off when my detector was put inside the box. The evaporator coil is leaking. Added some refrigerant and the unit started to cool down and cycled off on temperature. Need to quote.

Near E 4th St, Bethlehem, PA 18015
Service C.

Service C.

Found the Under Counter Refrigerator unit off. Turned on and tested. Found the compressor came on but the temperature in the box went up. One of the condenser fans did not work. There was no. heat being taken out of the box. Got a saddle valve and installed it. Found the refrigerant pressure at 0 PSI when on. Leak tested the system. My electronic detector only went off when my detector was put inside the box. The evaporator coil is leaking. Added some refrigerant and the unit started to cool down and cycled off on temperature. Need to quote.

Near E 4th St, Bethlehem, PA 18015
Service C.

Service C.

Checked range and found the rear pilots are all low or out . Tried cleaning them but it did no good . Reassembled and ran ovens to 350° and cycle. Temps calibration ok. Only had to adjust the right oven knob. Left and right ovens ok. All top burners work ok. Soap tested all connections and gas hose and quick connect and burner valves and thermostat lines and no gas leaks anywhere. Gas smell may have come from the pilots being out. Will order new pilot kits and return to replace. Unit in service. 9/4/20 Removed grates and burners. removed pilot assy. on all. replaced them with new. put unit back together and lit pilots. adjusted all and turned burners on 1 at a time. they all lit with pilot. unit is operational job complete.

Near Center St, Bethlehem, PA 18018
Service C.

Service C.

arrived onsite to check top Southbend convection oven. checked and found oven not heating. troubleshot and found broken burner igniter. also checked voltage from ignition module, no 24 volts. have voltage to module but no 24volts to igniter. ignition module also bad. checked truck stock for module and igniter, igniter damaged and no module. will need to order, return and replace. customer will start using this kitchen shortly, but not right now. 6/29/20 arrived onsite to repair top Southbend convection oven. accessed surface igniter and ignition module. proceeded and replaced hot surface igniter and ignition module. dressed wiring and brought oven into operation. allowed oven to heat and cycle a few times. oven in operation. Also removed foil impeded in fan blower wheel. foil impeded in wheel will cause uneven heat and hard on motor. oven in operation.

Near Schoenersville Rd, Bethlehem, PA 18017
Service C.

Service C.

Upon arrival found burnt wire connection near the compressor and also found restriction on the capillary tube of Prep Table. Repaired the wiring connection and tried to fix the restriction problem on the capillary tube by heating the tubing while flowing nitrogen gas throughout the system. Charged unit to manufacturer's spec. Started the unit and watched unit's operating pressure. Unit still show sign of restriction in the capillary tube, but it is working better than before. Talked to chef and explained what I did and will return to do a follow up next week. 6/15/2020 Returned to do a follow up on the unit. Customer is not on site. Look through the window and found the old unit was replaced by a new unit. I told customer that i have done everything I can to save old unit when i was here the last time. If it is still not cooling properly , then he will needs to buy a new unit. Talked to Rich D and explained everything to him, he said he will adjust the bill later.

Near Seidersville Rd, Bethlehem, PA 18015
Service C.

Service C.

The booster heater had a red light which is for a tripped hi limit. Found hi limit on tank was tripped. Reset. Burner came on and heated. Ran dishwasher. Final rinse temp is now over 185 and recovers okay. Noticed wash temp was at 111°. Found 20 amp fuse open. Replaced with new. Ran cycle. Wash temp now at 160. Rinse temp is over 200. Adjusted down to 170. Temp on side panel says it should be 165. Ran several cycles. All temps now within specs and recovering okay. Back in service.

Near Wood St, Bethlehem, PA 18018
Service C.

Service C.

Middle fryer on front line is reading ignition failure. Looked in sight glass and can see the flame but then it goes out. Checked connections. All secure. Checked microamps on both ignitor. The left ignitor was reading 2 and the right was reading 1.3. Blower is clean. Changed both ignitors. Turn on. Fryer now heating. Adjusted blower air shutter to get a good blue flame. Microamp readings are 2.6. Heated to temp. Back in service.

Near Wyandotte St, Bethlehem, PA 18015
Service C.

Service C.

Arrived to check bottom Angelo Po Combi oven. Power button was closed but screen was not powered on. Checked outlet. Oven was plugged in. Have 120v at outlet. Removed side and front panels. Checked incoming power. 120v to terminal block. Have 120v to power switch and 120v out of switch. Have 120v to the large transformer and 230v out. From there power goes to a 230v/12v transformer behind the control panel. Do not have 230v there. Had to trace out the wires. Found the black wire open. Checked the connections where wires were connected with butt connectors. Tugged on wires and the black wire pulled out. Put on another connector and crimped together. Turn on and now the screen powers on. Once the logo disappeared a warning appeared saying the CO2 and CO needs to be set up. Pressed OK and it gave an E20 error saying the set up is not correct. Need to obtain Flu Analyzer to set up gas. Rich D brought the analyzer. Set up analyzer. Tried setting up gas but was having trouble. Spoke to Leti

Near Wind Creek Blvd, Bethlehem, PA 18015
Service C.

Service C.

Arrived on site to check upper Hatco heatlamp. checked and found 2 bulbs burned out with bad sockets. checked and found heat element not heating. checked and found voltage, 209volts, to infinite switch, but none on output side when turned on. will order new parts, return and replace. per Frank, also quote to replace entire unit. unit also needs 6 wire guards that are missing. 1/15/20 arrived onsite to repair lower Hatco heatlamp. proceeded and isolated electrical circuit. proceeded to replace infinite control and indicator light. repaired burned up wiring. brought heatlamp in operation. element drawing aprox. 9.5 amps. allowed unit to heat in various settings. heatlamp in operation. customer needed access to steamtable for dinner service. will need to return to finish up burned out lamps. customer happy with heatlamps in service. can finish up when return with Blodgett oven parts. 1/17/20 arrived onsite to repair lower Hatco heatlamp. proceeded and replaced 2 lights and socket assembl

Near Wood St, Bethlehem, PA 18018
Service C.

Service C.

upon arrival checked in with Tess. found Booster Heater final rinse only 104 degrees. tested booster and found t stat open turned all the way up. replaced t stat and tested. dish machine was only reading 160. during rinse cycle. turned t stat until pop off blew off and back 1/8 of a turn. pop off not popping but gauge only reading 160 on dish machine. booster is okay. unit is operational, job complete.

Near Broadway, Bethlehem, PA 18015
Service C.

Service C.

Ventless Hood is off. Turned on. Anne-Marie said after an hour the motor got very loud. At first the motor wasn't loud but after a half hour it started getting louder. The motor was getting hot. The bearings are going bad. Need to replace the motor. Also need to order the wheel. Manny at BKI said the blower wheel sometimes doesn't come off easily and recommends cutting the shaft. Will bring a puller and heat and try to remove the wheel but if not then the shaft will need to be cut and a new wheel will need to be installed. Got part numbers from Manny. Spoke to Terri at shop. Parts are not in the system and she will do a P&A. Do not order parts until approved by customer. Terri called me with the prices. I gave them to Anna Marie. They said they will get the parts themselves and call us when they are in. Need to bring a tall ladder. Hood is tall. A short step stool will not suffice. Do not order parts.

Near W Broad St, Bethlehem, PA 18018
Service C.

Service C.

Metro warming cabinet - Maintenance says the humidity does not work. It just drops. The hot air thermostat must be satisfied before the humidity turns on. Both the water and hot air elements should not be on at the same time. I set the hot air at 160 and humidity at 35%. Once the hot air was at set point the heat light went off and the light for the humidity came on. It would cycle both elements, one at a time, to maintain set points. Once humidity element was energized I was getting 14-15 amps per leg. Let cycle a while and the cabinet held the set points. When the water element de-energized and the hot air element energizes the humidity will drop. Once humidity is resumed then the percentage rises and the temp will drop. That is normal. Spoke to Dave at Metro. He said the exact same thing. Cabinet is operating normally. Back in service.

Near Wind Creek Blvd, Bethlehem, PA 18015
Service C.

Service C.

arrived on site to check top Middle-by Marshall conveyor oven. checked and found oven not heating, everything else working. dropped control panel door and proceeded with troubleshooting. checked and found wire pulled out of middle switch contact block. contact block broken. extra contact block on right switch not being used. repaired center switch and moved extra contact block to center switch. wired contact block. proceeded and brought oven into operation. oven now heating. oven temperature set point at 425°. oven heated to 426° and cycled off. oven up to temperature. oven in operation. note: also cleaned cooling fans as best as I could.

Near Easton Ave, Bethlehem, PA 18017
Service C.

Service C.

problem is with the bottom right oven . power on and it shows service 37 and a service 36 which are pressure sensor issues . Turned on data window and checked the pressure sensor and have no voltage reading. Checked and have no power to the connection on the pressure sensor. Checked at the board behind the front panel and the connector for the pressure sensor was off the board. Put it back on and its tight . Run unit and now have the 12vdc at the pressure switch. In steam and combi modes the is 2.7v on the data window. Unit now running and no error codes . Cleared the error code list and unit starts up and no codes show up. In service

Near Fritch Dr, Bethlehem, PA 18020
Service C.

Service C.

Removed old unit and set new Follet Ice Machine in place. Hooked up water and drain lines and made sure there were no leaks. Machine is making ice.

Near Wyandotte St, Bethlehem, PA 18015

Planned Maintenance

A planned maintenance agreement can keep your equipment running longer than the factory warranty. Reduce cost, downtime and have your equipment running at top performance when you need it most.

We Do It Right The 1st Time!

See what our customers think about our service!

Great service Very courteous polite and knowledgeable The Gardens At Stroud Stroudsburg
Super Guys! The K & D Team of repairman are super!. always courteous, friendly and get the job done right! Answer my questions and never a surprise cost. Dunmore Health Care Center Dunmore
Maintenance Supervisor Shawn is a good Devoted Service Tech from your Altoona Offfice Steve Long is always a great help when i call him Mount Union School District Mount Union
Read More