Service C.

Service C.

checked oven, opened panel, noticed that the ignition blower motor is not running - checked voltage to motor, not getting 120v to motor. Called Middleby, was on hold for 20 min or more, spoke to Dennis to help me with troubleshooting. He had me check voltage to control terminal L2 to air switch getting 119v and per Dennis it's a bad air switch.. will order through shop and return unit not in service. 8/23/19 put in new pressure switch unit still did not heat up call the manufacturer twice two different texts keep telling me it's the pressure switches both Motors in the back are running both pressure switches are good because I checked them I blew through them lightly and they both have continuity but I am not getting any voltage to the ignition motor or coming out of the Transformer I blew through the lines of the blower motors in the back to see if they were clogged up but they're not I have exhausted my options will return with a more experienced technician next time unit still not

Near MacArthur Rd, Whitehall, PA 18052
Service C.

Service C.

Checked out proofer. bottom portion is proofer. customer had product in on arrival. waited til completed. customer has pan of water on bottom of proofer so can use. found that fan motor spins inside cavity. removed back panel. have 214 volts to unit. have 2.5 amp draw on each leg of elements. removed water line from humidity valve. have water into valve. removed cover inside cavity to get at water nozzle. checked have no clogs. checked and have voltage into solenoid valve but not letting water through. unit needs new valve. got part number. Will order through shop and return. unit is in service. 3/13/19 arrived on site to repair Duke Proofer. accessed rear of unit. removed rear panel and proceeded to replace water solenoid valve. replaced valve. brought proofer into operation. allowed unit to preheat temperature of 105°. initiated proof cycle at 80% for 1 hour. checked for water leaks - none present. allowed proofer to operate for a period of time ensuring proper operation. proofer in

Near West St, Whitehall, PA 18052
Service C.

Service C.

Unit cuts out to reset with both compartments running. Not kicking out on low water. Called Groen and spoke to Gabe who thinks its relay. Also, drain box is leaking. Cavity hoses will need replacing. Will order parts. 3/24/17 Returned and replaced drain box. Had to take flu cover and flu back off unit to get to hoses. Replaced cavity hoses. Relay sent was different brand than what was in unit. Had to figure out where wires went. Ran unit up to steam . Unit cuts out when you use both compartments. Took video of it. Going to send to Groen. 4/3/17 Tried jumping pressure switch. No change. Called Groen and spoke to Steve White. He said remove probes and see if hole in baffle is open on each probe section. Poked a pick in them. Reassembled and tried unit. Ran 4 cycles with both compartments on. Unit did not kick out. Needs deliming. Drain valve does not work. Maintenance is going to work on it.

Near Fellowship Dr, Whitehall, PA 18052
Service C.

Service C.

Disassembled and installed new cord set. Replaced wire nuts and re taped. Tested to make sure unit works (heats). They found other unit in back hallway. Need to obtain strain relief for new cord.

Near Lehigh Valley Mall, Whitehall, PA 18052
Service C.

Service C.

Tested and found both pilot out. Tried to light but they would not, Removed a pilot line and depressed safety. Smelled no gas. Found relief plug on regulator blocked with grease. Removed and lit pilots. Heated grill up. Unblocked grease and burnt off with torch. Little ball moves freely now. Put back in and tested. Grill works. If it happens again the 3/4 regulator valve should be replaced.

Near Grape St, Whitehall, PA 18052
Service Check-In ..

Service Check-In ..

WELLS- DROP IN HOT WELL Tech - Found wire connector burned off at element connector. Cut back wire and crimped on new connector. Reassembled. Unit now heats.

Near Lehigh Valley Mall, Whitehall, PA 18052