Found Reach-In Cooler unit with box temperature of 26°f. with compressor still running. Found temperature control stuck closed. Freed temperature control and set to warmest setting. Box temperature holding at 33°. Will need temperature control replaced. 11/22/19 Removed temperature control, installed new temperature control, allowed unit to come down to temperature, temperature holding at ~34F, tested operations confirmed unit working correctly at this time

Near Sycamore Rd, Montoursville, PA 17754
Service C.

Service C.

Ran Dishwasher unit through startup, found wash tank heaters not energizing. Found hi limit tripped. Reset high limit and ran diagnostics on each function. All systems passed. Ran unit through several cycles. Machine drained and operated normally. Found detergent leaking from rear of unit around detergent chute. Will order new gasket and return. 10/28/19 Removed failed chute gasket and replaced. While here unit exhibited draining issue from original call. Checked over unit found draining is not the issue. The unit is actually over filling the booster tank causing water to over fill wash tank through the detergent chute. will order new fill valve. 10/30/19 Replaced valve, turned on checked for leaks found okay, allowed to fill and heat found okay, ran through cycle found okay, drained unit found to drain properly. Unit is operating correctly at this time. Final temps were wash 160 and rinse 180.

Near PA-87, Montoursville, PA 17754
Service C.

Service C.

Found Ice Machine unit not energizing in ice mode. Found energizing in wash mode. Checked switch, found okay. Found bin switch actuator installed backward. Removed actuator, reinstalled, energized unit and checked operation - unit operating normally at this time.

Near Sycamore Rd, Montoursville, PA 17754
Service C.

Service C.

Removed Reach-In Cooler failed condenser fan motor, door magnet and door switch and replaced. Energized unit and checked operation. Unit operating normally at this time.

Near Mulberry St, Montoursville, PA 17754
Service C.

Service C.

Removed Combi Oven latch cover plate and inspected latch mechanism. Found spring broken. Parts not sold separately, Needs left hand latch assembly. 5/15/19 Removed failed latch assembly and replaced. Checked operation unit operating normally at this time.

Near Warrensville Rd, Montoursville, PA 17754
Service C.

Service C.

Found Electric Oven door hinge bent. Attempted to bend piece back. Was able to refasten hinge onto unit and door is operable at this time. Will order new hinge and return to replace. 2-27-19 Removed failed hinge and replaced.

Near Warrensville Rd, Montoursville, PA 17754
Service C.

Service C.

Found Dishwasher unit with very little water flow to tank when filling. Took over 20 min. to fill and went into low water error. Removed solenoid valve and cleaned inlet strainer. Removed strainer and cleaned screen. Unit filling in 5 min. now. Strainer and solenoid valve corroded internally and should be replaced.

Near Willow St, Montoursville, PA 17754
Service C.

Service C.

Removed top steamer failed door seal, drain valve and door latch assembly and replaced. Unit operating normally at this time. **Travel Charges Billed on wo# 167076**

Near Warrensville Rd, Montoursville, PA 17754
Service C.

Service C.

Found MFO Steamer unit on with Door gasket leaking and drain valve stuck shut. Will order parts and return to replace. **Travel Charges Billed on wo# 167076**

Near Warrensville Rd, Montoursville, PA 17754
Service C.

Service C.

Found BLO Combi Oven unit off. Turned on and found fan would not spin, pushed fan, it started to turn, will need capacitor. 8-8-18 Removed failed capacitor and installed new capacitor. Energized and checked operation. Fan still would not start. Checked capacitor micro ferrods, found 5.09uf on a 5th capacitor. Checked voltage to motor, found. Correct. Unit needs new blower motor and blower wheel. 8-15-18 Removed blower wheel and failed motor. Replaced motor and blower wheel, energized and checked operation. Found motor would spin without blower wheel Installed. Checked frequency drive, found under load driver will not select proper frequency to run motor. Driver will need replaced. 8-24-18 Found unit off. Removed side cover replaced old inverter drive kit. Started unit, brought unit to operating temp. Tested blower at all speeds. Found okay. Unit is operating normally at this time.

Near Warrensville Rd, Montoursville, PA 17754
Service C.

Service C.

Checked operation on SBR Range and the unit was trying to light but the igniter is bad. It was receiving 120 volts but wouldn't lite up. When I moved the unit it tripped the breaker from the cord being damage. The staff is running over it with the wheels and spreading it. I replaced the cord and put the unit back together but we will need to order parts and return to install. 6-18-18 Replaced igniter and tested, all okay at this time.

Near N Loyalsock Ave, Montoursville, PA 17754
Service C.

Service C.

Checked over microwave oven unit, found fan not blowing. Removed fan and checked. found locked up tried to free but was stuck. Replaced with new, tested okay. Had customer run with product found unit okay.

Near N Loyalsock Ave, Montoursville, PA 17754
Service C.

Service C.

looked over convection oven unit, found timer knob insert spinning freely, will need new knob, customer stated issue with lighting again, found left spark assembly not sensing flame, will order 2 iginitors and return to replace. 11-20-17 Pulled unit apart and removed the old ignitors and installed new ones. Then put unit back together. Then removed old timer knob and installed new one. Then checked for leaks and operation. The unit is running fine at this time.

Near Sycamore Rd, Montoursville, PA 17754
Service Check-In ..

Service Check-In ..

Henny Penny- Electric Fryer found unit off, energized unit, cycled through melt cycle and warm up. Heated to set point of 230*F for melt cycle and heated to set point of 350*F and cycled normally. Watched employee cook several items. Checked amp draws at elements, all operations normal. Found no issues with fryer or hood at this time.

Near N Loyalsock Ave, Montoursville, PA 17754