Recent Jobs and Reviews in Kingston, PA

Job Locations and Reviews

Daniel  D.
Daniel D. Checked in
When the garbage disposal is turned on, there is an unusually loud noise. Did not find any obstructions, blockages or issues with the blades being worn out. Found that the noise is coming from the motor bearings that are failing. Will replace the entire garbage disposal with a new unit from the manufacturer.
Kingston, PA 18704
Mark B.
Mark B. Checked in
Arrived at location on 9/13/22 - Examine unit found F5 fuse blown extra fuses in oven replaced fuse. Oven turned on activated cook cycle fuse blew called Blodgett spoke Travis went into programming. When activated fan motor fuse blew Travis said inverter bad will order motor inverter and fuses per Travis order parts overnight Q.W.P Returned to location on 9/16/22 - Service motor inverted different called Blodgett took a picture of side of oven with panel off e-mail Blodgett picture replaced F5 fuse oven came on and up to temp customer cook in oven
Kingston, PA 18704
Mark B.
Mark B. Checked in
Arrived at location on 10/11/21 - Arrived to location and spoke to Dave. Checked incoming supply pressure and found it was 5.0 in/wc. Adjusted main regulator at tank until unit had 10.0 in/wc. Lit unit and ran for 20 minutes. Flames were blue and seen no soot leaving unit. Recommended that supply reg from tank be replaced. Dave stated that he will order and replace regulator himself. Unit back in service.
Kingston, PA 18704
Mark B.
Mark B. Checked in
Arrived at location on 7/6/21 The old gaskets were removed and the new ones were installed. Care should be taken with the closure of doors for now until the gaskets setup correctly. Atm the doors do close.
Kingston, PA 18704
Service C.
Service C. Checked in
Upon arrival Salad Bar unit was on and stocked with product. Customer complaints that the temp seemed off they think it might need refrigerant. The box temp was at 38 degrees Fahrenheit. After this happened the compressor kicked on. The unit was searched for leaks. The leak detector did not go off inside the evaporator but it did in the condensing unit area when unit was on. Soap bubbles were used in various places to try and locate a leak no leaks found. The unit satisfied and the the leak detector did not go off at the condensing area . This could be a false reading, the box was satisfied upon arrival and satisfied 2 times while troubleshooting Evaporator air temp was as low as 30 degrees Fahrenheit. At this time the unit's charge seems fine.
Kingston, PA 18704
Service C.
Service C. Checked in
Found Reach-In Freezer unit short cycling on low pressure switch. Leak checked unit found no leaks. Recovered refrigerant 28 oz. Removed capillary tube and cleared blockage at outlet. Reinstalled capillary tube, pulled vacuum, charged and checked operation. Adjusted pressure control. Unit operating normally at this time.
Kingston, PA 18704
Service C.
Service C. Checked in
Shut electric steamer unit down, drained unit, cleaned out grease in bottom of unit, cleaned probes - had customer run bottom shelf through dish washer, retested all panels etc., tested okay
Kingston, PA 18704
Service C.
Service C. Checked in
Examined Ice Machine unit. found evaporator solid block of ice. removed ice from evap and cleaned ice maker per manufacture instructions. water pressure low and filter restricted, Dan had to run for filter. replaced water filter and bled water line. reassembled unit and tested. unit made ice. discarded first batch and waited for second to drop. good to go. Believe low water pressure was main cause of not making ice.
Kingston, PA 18704
Service C.
Service C. Checked in
Cleaned water pt probes and descaled electric steamer, flow through filters at 50psi, filters good, tested operation, tested good.
Kingston, PA 18704
Service C.
Service C. Checked in
Found the Reach-In Cooler unit in the defrost cycle. Was told the unit goes into defrost often and asked if this was normal. Could not answer the question. The unit came out of defrost and cooled down to 37 degrees Fahrenheit and then took its time. Put gauges on the unit and the suction pressure was low at 8 PSI. Added refrigerant to bring the pressure up to between 15 and 20 psi.. The unit cooled down to 34 degrees Fahrenheit and then came back on at 40 degrees Fahrenheit. Moved the set points to come on at 37 degrees Fahrenheit and off at 33.5. Found a piece of paper blocking some air flow in the evaporator. The unit went into defrost again so I called technical service and talked to Becky. She said the unit will go into defrost every hour and say defrost for about twenty minutes an hour. Leak tested briefly but did not find a leak. If the unit losses its refrigerant again a more the leak will have to be found and fixed. The unit is up and running.
Kingston, PA 18704
Service C.
Service C. Checked in
examined unit, dishwasher running fine, getting a fluctuation in incoming pressure from feed line. found several old valves and an old regulator ( probably not working ) and found a new regulator on the incoming line at the dish machine - talked with Dave (dietary) and Eric (maintainence) and discussed what is called water hammer, the in maintainence department will handle the changes needed to the incoming water supply line.
Kingston, PA 18704
Service C.
Service C. Checked in
Moved the Reach-In Cooler unit to the back. Disassembled and replaced the capillary tube and drier. Reassembled and pressure tested with nitrogen for half an hour then evacuated to below 500 microns. Charged by weight and tested. The unit shuts off at 34 degrees Fahrenheit. Resealed the top.
Kingston, PA 18704
Service C.
Service C. Checked in
removed and replaced Food Warmer blower. tested unit, heats and blows air around. Note: unit is missing back panel on heater assembly.
Kingston, PA 18704
Service C.
Service C. Checked in
replaced Garland Convection Oven motor and blower assembly, rewired and tested, all okay.
Kingston, PA 18704
Service C.
Service C. Checked in
Examined Steamer unit, found inner edge (hinge side) door gasket folded over, found tacky residue around the cavity opening. Cleaned off with a green scrubby, adjusted door assembly, fixed door gasket, started unit and tested all okay.
Kingston, PA 18704
Service C.
Service C. Checked in
examined convection oven top unit, found only heating to 370 when turned to max temp. temp controller is original to unit, controller is defective. will order temp controller and probe and return. 3/8/19 removed old temp controller and probe, replaced with new. calibrated the temperature knob. unit heats and cycles.
Kingston, PA 18704
Service C.
Service C. Checked in
Examined Electric Oven unit, customer stated product not cooking correctly and no shine on bagels. Checked temperatures, oven display on temp within 4% of tech temp meter, removed water lines from solenoid and checked for obstruction, none found. Spoke to Blodgett, they said when unit activates water, should be for 1 minute about 6 ounces of water. Went into programming and activated hydro for one minute only had 3 ounces of water, turned flow meter from 3 to 4, tested again, had 6 ounces of water, good. Customer will use and advise
Kingston, PA 18704
Service C.
Service C. Checked in
Found first Hot Well on the right element short out and metal which holds element in place rusted away, need part (1)2406 dome element. 2-4-19 Disassembled and installed the new heating element. Reassembled and tested. Element draws 2.2 amps. and the infinite control cycles on low.
Kingston, PA 18704
Service C.
Service C. Checked in
Examined Vulcan oven unit. Found bottom element in oven bad. Will order parts and return. 8-3-18 Removed the old element and installed the new element. Put a new electrical connection on element. Tested
Kingston, PA 18704
Service C.
Service C. Checked in
Installed a new temp read out on walk in cooler and walk in freezer
Kingston, PA 18704
Service C.
Service C. Checked in
examined unit, pump is working, starts off good #1 but slows down #2 and #3, told them to change filter paper. This will help, other wise they can replace pump and motor assembly at a cost of 1500 to 2000
Kingston, PA 18704
Service C.
Service C. Checked in
Found JTC Dishwasher unit would not go through cycles, temps are okay. Shut power off and pulled unit out, removed top - found toner motor fell of timer cam and start cycle switch is also falling apart. Made temporary repairs to get customer in Service. Need part numbers JTD-20518 timer and JTD-20519 cycle switch Note: quoted additional repairs of $486.84 (wo# 151931).
Kingston, PA 18704
Service C.
Service C. Checked in
Removed all ice from the ice bin on HOS Ice Machine. Ran ice machine cleaner through the unit. Removed the water distribution tubes and cleaned. Wiped down the ice machine, rinsed, then sanitized with ice machine sanitizer. Allowed unit to make a batch of ice and disposed of it. Replaced water filter gotten from maintenance.
Kingston, PA 18704
Service C.
Service C. Checked in
Examined microwave oven unit. Found interlock bad, fuse blown, inner door plastic cracked and a lot of play in door. Will order parts and return. 9-15-17 Examined unit. Replaced inner door, door weldment, washers, fuse and interlock switch. Put back into service and tested.
Kingston, PA 18704
Service C.
Service C. Checked in
Examined Ice Machine unit. Gauged system and found low on refrigerant. Leak checked and found leak on liquid line access port. Tightened fitting and checked. Brought up to charge. Checked 4 cycles.
Kingston, PA 18704

Planned Maintenance

A planned maintenance agreement can keep your equipment running longer than the factory warranty. Reduce cost, downtime and have your equipment running at top performance when you need it most.

We Do It Right The 1st Time!

See what our customers think about our service!

Great service Very courteous polite and knowledgeable The Gardens At Stroud Stroudsburg
Super Guys! The K & D Team of repairman are super!. always courteous, friendly and get the job done right! Answer my questions and never a surprise cost. Dunmore Health Care Center Dunmore
Maintenance Supervisor Shawn is a good Devoted Service Tech from your Altoona Offfice Steve Long is always a great help when i call him Mount Union School District Mount Union
Read More