Recent Jobs and Reviews in Hanover, PA

Job Locations and Reviews

Mark B.
Mark B. Checked in
Commercial Kitchen Equipment Repair Service. Arrived at location on 6/16/23 - Unit was at proper temperature and cycled off when I arrived, I cycled unit several times with no problems, I found unit set at 34 degrees which I changed to 37, since air probe was a problem previously I recommend we replace probe, customer would like part ordered and replaced. Returned to location on 6/26/23 - Replaced control sensor and waited for unit to come down to temperature and is working properly at this time.
Hanover, PA 17331
Mark B.
Mark B. Checked in
Arrived at location on 12/29/22 - While on-site. Noticed start button missing off the disposal by dishwasher. Ask manager and he said yeah. Needs fixed. It works. But he hardly ever uses it. Adam said order part. Call to ID part. Returned to location on 1/4/23 - Replaced start button on disposal by Dishwasher. Tested. Completed.
Hanover, PA 17331
Mark B.
Mark B. Checked in
Arrived at location on 7/8/22 - Installed filter system and ensured no leaks, unit working properly.
Hanover, PA 17331
Mark B.
Mark B. Checked in
Arrived at location on 6/20/22 - While on site for other issues Jessica asked me to look at the sink to the right of the sauté line. She also wanted me to look at the drain for the hot well at the right of the sauté line. Found cold water side leaking on the valve. Hot side didn’t look good either. The drain line runs very hot water down it and has disintegrated the drain valve. Went to APR supply in new Oxford and gathered all parts needed. They needed to order the TNS brass parts. They will be available for pick up tomorrow morning. Returned to location on 6/21/22 - Picked up parts from APR supply in new Oxford and drove to site. Made new drain line with new valve and installed. Replaced both sink cartridges and turned water on. There is no more leak at the drain line or the sink valve. The hot well that the drain goes to is deteriorating at the bottom and is leaking slightly. I advise Jessica on this so she is aware. Complete
Hanover, PA 17331
Mark B.
Mark B. Checked in
Arrived at location on 6/1/22 - Upon investigation I found that the drain line hose was knocked out of the drain pan. I repositioned drain hose back into pan. Unit is running properly as of now.
Hanover, PA 17331
Mark B.
Mark B. Checked in
Arrived at location on 5/18/22 - Replaced motor and hub on ice cream machine condenser, tested and is working properly at this time.
Hanover, PA 17331
Mark B.
Mark B. Checked in
Arrived at location on 4/6/22 - Checked over unit is cooking now checked micro amp at 1.9. Is good. Checked temp is ok. Gauge is at green no pressure. Pulled apart is full of grease. Will need to order gauge then come back when not busy and take weight apart and clean. Returned to location on 4/22/22 - Pulled weight assembly. Cleaned all fittings. Went to put new gauge on, it’s defective. So put old gauge back on. Heated unit up, had my drop fries. Went to green, blew off as should. U it working fine. Completed. Returned to location on 4/27/22 - Replace defective gauge, 1st time out, new one was defective. So came back to replace. Completed
Hanover, PA 17331
Mark B.
Mark B. Checked in
Arrived at location on 3/9/22 - Found drain pan frozen from unit being turned too cold, also condensation is accumulating on ceiling of unit because some gaskets are torn at corners and getting worn and magnet not sealing to cabinet properly, I thawed evaporator drain pan and blew out to ensure clear, customer is going to source gaskets themselves.
Hanover, PA 17331
Mark B.
Mark B. Checked in
Arrived at location on 3/7/22 - Bottom pizza oven, pilot lit but burner would not light. Heated the mercury bulb with lighter, got it to fire off. Cleaned bulb. Adjusted pilot up higher. Cleaned pilot best could without taking chance of breaking bulb. Did not try to remove pilot or bulb. When do it breaks most of the time. Oven lit now. Working. If quits again will probably have to do the upgrade kit and new stat. Plus would replace the gas shut off valves that have vise grips on them now. Completed. Working at this time.
Hanover, PA 17331
Mark B.
Mark B. Checked in
Arrived at location on 2/28/22 - The ice was too thick so I checked both floats and they were working. I watched unit fill at the beginning of the cycle and the water pressure was very high, and the reservoir overflowed. I was able to close the ball valve slightly to reduce the flow rate to the machine, and the reservoir filled to the proper level and then made a normal sheet of ice.
Hanover, PA 17331
Mark B.
Mark B. Checked in
Arrived at location on 2/6/22 - Went to light pilots and not getting gas through pilot. Checked gas pressure on manifold and had no pressure. Inspected quick disconnect and found in poor condition and not having proper functions anymore. Also found gas regulator not letting gas through. Replaced regulator and quick disconnect and now am able to light pilots and burners. Found thermostat control for far right burner stuck on and has no control. This will need to be replaced. Also found knobs worn, broken and missing. Will obtain replacement thermostat and knobs and return. Unit functions at this time and ok for use. Returned to location on 2/21/22 - Verified model and serial. Right griddle, far right stat. Replaced stat control for griddle. Heated to 375, wants set to 200. No leaks seen. Put cover back on. Put on 4 new knobs. Could not collect payment. Completed.
Hanover, PA 17331
Mark B.
Mark B. Checked in
Arrived at location on 1/17/22 - Box temp is 14 degrees but temp control is showing -19 Tempted probes and air probe and coil probe are bad according to temp and ohm chart in True booklet. Recommend replacing all 3 probes. Returned to location on 1/24/22 - Picked up parts and changed probes. Unit temperature dropped.
Hanover, PA 17331
Mark B.
Mark B. Checked in
Arrived at location on 10/4/21 - Lit pilot only have 298 mv on thermopile. Cleaned pilot went up to 300. Will order thermopile. Brought up to temp tested ok. Returned to location on 10/5/21 - Installed new thermopile, started unit back up and allowed to come up to temp. Unit satisfied and pilot stayed lit. No further issues.
Hanover, PA 17331
Mark B.
Mark B. Checked in
Arrived at location on 8/11/21 - Customer explained kettle is trying to light but it will not light at all, pulled side over and inspected wiring and module all look good. Flipped kettle and pulled flame sensor attempted to clean. Tried to start unit up and could see unit spark, then fire, then go out. I believe unit is not sensing flame properly. Need to order flame sensor to repair unit. Returned to location on 8/13/21 - Installed new ignitor and flame sensor, tested and verified operations. No further issues.
Hanover, PA 17331
Mark B.
Mark B. Checked in
Arrived at location on 7/19/21 - Installed new filter system, checked for leaks, were none. Operation ok at this time.
Hanover, PA 17331
Mark B.
Mark B. Checked in
Arrived at location on 6/24/21 Fork jammed in disposer. Took me and Don both to get it out. Was really bad. Completed. .
Hanover, PA 17331
Libby D.
Libby D. Checked in
TRANE HVAC System - 04/13/21- Shawn- Manager showed me where water was leaking. Went on rooftop and located unit. Unit is covered in roofing patch material. Attached pics and let Matt know the issue with the unit leaking . He said he would talk to Christine
Hanover, PA 17331
Service C.
Service C. Checked in
removed VHL Griddle left element, is blown, will give estimate for repair. 3/26/21 Installed new element provided by customer, tested and verified operations. No further issues. Finished repair at shop - no charge Miles & Travel
Hanover, PA 17331
Service C.
Service C. Checked in
Arrived, checked and found HAT Booster Heater unit was on. ran unit, found amp draw was steady. Found water pressure steady. Customer stated that the issue happened when they first started it in the morning and worked ok the rest of the day. Thermostat may be slow to rise will obtain new and return. 02/24/21 Customer said had no further issues, gave part to John.
Hanover, PA 17331
Service C.
Service C. Checked in
Customer Comments: Replacing the heat exchanger for Carrier RTU - Removed and replaced bad heat exchanger. Ensured that the system is operating properly at this time.
Hanover, PA 17331
Service C.
Service C. Checked in
Rear window air curtain: No blown fuses. So outdoor blower works but outdoor heater does not. So either bad stats or bad heater. Can't verify until can pull outside covers and shut down that drive thru window. 10/19/20 Block drive thru with cones and ladder. Pulled cover. Ohmed out heaters and stats. All show ok outside. Has bad fan capacitor. So either need to get new fan capacitor or new blower from Dennis. Other issues inside. Bad power switch, bad wiring or board, had weird voltages. Waiting on Ready Access to verify parts. 10/23/20 Replaced outdoor blower on rear window. Hooked wiring back up inside. Heater amps 13.9 both heaters outside. 14.9 ohms both outside heaters. Blower is dual voltage. Had 120v summer mode, 208v winter mode. Blower amps .85. Put correct fuse in front air curtain. Left spare pack 3 GMD3R amp fuses in front and rear units. Due to hard to find. Completed.
Hanover, PA 17331
Service C.
Service C. Checked in
03/05/20 Removed and installed customer supplied Traulsen 2 glass door reach in cooler, Installed casters and leveled up unit. unit came down to temp and satisfied. Removed and disposed of old unit.
Hanover, PA 17331
Service C.
Service C. Checked in
Replaced Gas Fryer limit supplied by customer. Brought up to temp. Tested okay.
Hanover, PA 17331
Service C.
Service C. Checked in
Per customer-Pilot won't stay lit on range: Cook top burner pilot not staying lit front right burner. Pilot tube clogged. Sherri agrees, should replace all 12 pilots on stove top. Will order pilot tube kit. Will return to replace. 12/6/19 -came in and replaced 10 pilot tube assembly. tested the unit and unit is firing okay. all the burners are working and the pilot is staying lit.
Hanover, PA 17331
Service C.
Service C. Checked in
Replaced Convection Oven door switch, tested okay - also locks out igniter bad, will order. 10/18/19 Installed igniter. Brought up to temp. Tested okay.
Hanover, PA 17331

Planned Maintenance

A planned maintenance agreement can keep your equipment running longer than the factory warranty. Reduce cost, downtime and have your equipment running at top performance when you need it most.

We Do It Right The 1st Time!

See what our customers think about our service!

Great service Very courteous polite and knowledgeable The Gardens At Stroud Stroudsburg
Super Guys! The K & D Team of repairman are super!. always courteous, friendly and get the job done right! Answer my questions and never a surprise cost. Dunmore Health Care Center Dunmore
Maintenance Supervisor Shawn is a good Devoted Service Tech from your Altoona Offfice Steve Long is always a great help when i call him Mount Union School District Mount Union
Read More