Found IMP Range units idle, tagged and etched all imperial units with all specs according to imperial and code. took pictures and sent to customer and to inspector and got approval from both. all units are now marked with the model number, converted to natural gas, w.c, and NSF tag number. all units now certified and up to code.

Near Northland Center, State College, PA 16803
Service C.

Service C.

While working on grill heard fryer popping. Popping coming from center vat. Removed combustion blower and ignitors. Found right side ignitor damaged. Pilot tube almost gone. Inspected burners for cracks and found none. Replaced ignitor and started unit. Heard another pop on first ignition. Lowered manifold pressure to 3.1"wc. Let unit heat and heard no more popping. Unit heating normally and ok at this time.

Near E College Ave, State College, PA 16801
Service C.

Service C.

found Bottom Oven unit off. replaced control. turned on. found no power. inspected. found disconnected wiring at resets and safety switch. tested switch and breaker found okay. reconnected wiring. ran found normal operation. let heat. came to set point 470. found unit cycled normally. customer tested product. found okay.

Near Hetzel St, State College, PA 16801
Service C.

Service C.

Found top combi oven water supply line leaking. Will need to replace supply line. Cleaned up excess water. Will obtain supply line and return. 11/14/19 Removed faulty supply line. Checked water pressure and okay. Installed new water supply hose. Checked for leaks and tested unit. Ran in steam mode and steaming normally. Unit okay at this time.

Near Westerly Pkwy, State College, PA 16801
Service C.

Service C.

Call out - Found Reach-In Cooler unit low on charge, found small leak at flare fitting on receiver. I was able to get 1/2 turn on it and checked again and unit not leaking any longer. I used electronic tester and went over evaporator and condensing unit found no other hits, charged system to 80% receiver level and system dropped in temp, system is working properly now.

Near Country Club Ln, State College, PA 16803
Service C.

Service C.

Removed faulty control and installed new control on Walk-In Freezer. Set high and low pressure switches. Tested for leaks found none. Ran and cycled system okay. Insulated line that was rubbing on condenser box housing.

Near Country Club Ln, State College, PA 16803
Service C.

Service C.

Customer stated hi limit tripping. Inspected unit and doesn't seem to be over heating. Relay not sticking so hi limit tripping early. Will order hi limit and return. 10/9/19 Removed bottom of unit. Removed faulty hi limit and cover plate. Installed new hi limit and mounted capillary bulb with spacer and mounting plate. Put components back together and tested. Unit heated to temp normally. Okay at this time.

Near S Atherton St, State College, PA 16801
Service C.

Service C.

Customer stated outlet stopped working on Warming Cabinet. Turned off breaker to outlet. Pulled outlet from wall and checked wiring. All wiring secure. Turned on breaker and checked voltage. Found 115v to outlet. Put outlet back in wall and tested. Found 115v out of outlet. Removed plug from power cord. Cut back wiring and hooked up fresh wiring. Tested and unit working normal

Near N Atherton St, State College, PA 16803
Service C.

Service C.

Found Dairy Dispenser unit showing empty on slot A but not, and not dispensing. Spoke with tech support at Silver King and re-calibrated unit. After calibration, unit working normally. After emptying product, found inside very iced up. Removed build up before restocking product. Unit okay at this time.

Near S Atherton St, State College, PA 16801
Service C.

Service C.

When powered on glove steamer unit not heating. Checked for voltage from relay to element and found high limit tripped. Unable to reset hi limit. Jumped out hi limit and unit started to heat. Hooked hi limit back up. Will need to replace hi limit. Will order and return. 08-13-18 Removed faulty limit and installed new limit filled with water and cycled 4 times. Unit is in proper working order at this time.

Near Colonnade Blvd, State College, PA 16803
Service C.

Service C.

Need parts for Hatco heat lamp, will order. Travel+Miles on PM wo#156435 6-06-18 Removed faulty switch and element and installed new ones. Powered up unit and tested. Unit OK at this time.

Near Country Club Ln, State College, PA 16803
Service C.

Service C.

Found conveyor tripping reset. unable to manually spin conveyor. inspected and found chain links hung up on conveyor cross section and bent links. removed conveyor from unit and was able to free links and bend back straight. put conveyor in oven and tested. unit ok at this time.** No charge per Service Manager

Near Hiester St, State College, PA 16801
Service C.

Service C.

Found 4 Groen steamers in main kitchen flashing delime. Inspected. Found flow to units when filling at 20Psi. Sent messages to increase flow/ dynamic pressure to a min of 30psi to a max of 60 psi.

Near Westerly Pkwy, State College, PA 16801
Service C.

Service C.

Found dishwasher unit in use. Found temps for rinse and wash low. inspected components Found booster heater bundle has two bad heat circuits. rewired to use spare circuit. tested. Okay but needs replaced. found wash tank left element failed. will replace as well along with gaskets. scheduled for service this evening. got parts from storage and placed in electrical compartment. closed up. filled. let heat. - Removed faulty booster element and wash element and installed new ones. tested and unit okay at this time.

Near E Park Ave, State College, PA 16803
Service C.

Service C.

Found discharge line froze up box temp high. Found discharge side of filter drier froze up indicating a restriction. Had to get drier from Supply house returned and pumped system down installed new drier and pulled vacuum on low side. Released charge and checked for leaks around drier. System was low on refrigerant charged with 5lbs of r22 to full sight glass. Box is coming down to temp. Found king valve on receiver leaking put on a good cap and sealed with leak lock. Will return to check for leaks. 01-19-18 Checked evap coil and box temp okay. Went to roof to check sight glass and compressor operation, sight glass is full and comp cycles properly.

Near W Park Ave, State College, PA 16803
Service C.

Service C.

Upon arrival box temp at 92 degrees on Reach-In Cooler. Comp was running with low side in a vacuum high side also low. Leak detector was hitting in evaps section. Removed coil and charged system with nitrogen found leak on loops with soap. Customer would like estimate for repair to determine if unit needs replaced or repaired.

Near Innovation Blvd, State College, PA 16803
Service C.

Service C.

Found dishwasher unit on. Informed booster not heating. Inspected unit + found not responding to first reed switch activating + sending water to booster. Checked reed switch + working normally. Found 10K4 timer relay not working normally. Relay was stuck, & not switching after timer was complete. Reset power to entire unit & timer relay began working. Will order new timer relay. Unit OK to use until part arrives. NOTE: Also adjusted conveyor stop switch so it stops conveyor sooner. 10/10/17 Found unit on. Inspected & found booster reservoir not filling. Bumped float switch and reservoir filled and booster started heating. Replaced float switch and ran unit. Unit heating normally at this time. 10/11/17 Found unit on. Removed power + replaced + rewired new timer relay. Started unit + activated switch. Relay counted down properly. Unit OK at this time.

Near E Park Ave, State College, PA 16803
Service C.

Service C.

Found range unit to have weak spark. Lights, but takes a long time; too long. Also there are times when it will not spark at all. Will order parts and return in the evening to fix. 9/27/17 Found unit on. Removed bad ignition module. Installed new module with stand off so there is a one-inch gap for airflow so does not get as hot. Removed ignitor + adjusted 8 times to get to light consistently. Unit still not lighting perfectly. If problem persists, may need new pilot assembly. Call if further issues.

Near W Park Ave, State College, PA 16803
Service C.

Service C.

On arrival plate warmer not being used. Turned on unit + found bottom blower making noise. Removed plates from one side + turned on again. Found blower to motor very loose. Motor has bad bearings. Ordering new blower + motor. Jim p/n Motor unavailable - 08-24-17 On arrival plate warmer hot. Removed back cover. Removed 8 screws from back motor mount board + removed blower from motor and then removed motor. Taking motor to motor shop in Altoona. NOTE: [Customer] Mark does not want old motor re-installed. 09-28-17 Install old motor after fixing at [K&D] shop. Tested operation, working.

Near Cliffside Dr, State College, PA 16801
Service C.

Service C.

Found unit on. Unit was pointed out as one called in with fluctuation issue. Inspected. Found wire on ready light broken off. Repaired. Cleared fuzz from louvers. 20 Amps per leg of power. 11 Amps per element leg. 2 run amps on motor. Ready light cycles with T-Stat normally. Found door switch stuck closed. Freed, but does not open on every cycle of the door. Will need new door switch. Found outlet upside down, causing stress on power wire. Maintenance should rotate 180* . At 400*F set point cycled off at 400*F, Rose to 407*F,cycled back on @ 395*F, off at 407*, up to 412*, on at 396* off at 405* up to 410*. T-Stat OK. - 9/1/17 Removed faulty door switch. Installed new door switch (MON1299-8). Tested operation OK. - ** No charge travel and miles per Service Manager

Near W Park Ave, State College, PA 16803
Service C.

Service C.

Found unit on. Removed control box and disassembled. Found element power wire off of element. Connector very loose on terminal. Tightened connector and re-secured to element. Unit heating but display jumping temp display all over. Need to replace digital display. Will order and return. 8/4/17 CALLOUT -- Removed faulty display and installed new one (METRPC13-237 Temp Display). Ran unit and let heat to temp. Unit OK at this time.

Near E Park Ave, State College, PA 16801
Service C.

Service C.

Looked over machine, started troubleshooting rinse system. Customer needed to use machine and I also needed other tools from shop; will return in the early morning to finish. 1/5/17 Removed drain body on wash tank and replaced, also removed and replaced rinse thermometer and aux wash thermometer. Upon filling machine found machine to keep filling. Found aux float not working properly. Contacts for max position not making. Removed and replaced with one from customer stock. Will order one to replace stock. [Installed 15 parts. (3 each of 5 parts)]

Near E Park Ave, State College, PA 16803
Service C.

Service C.

Checked and found compressor to be getting proper voltage going off on overload at 27 amps. Locked rotor amps 33. Faulty compressor. Will order new compressor. -- Reclaimed charge, removed faulty comp., installed new cmp. New comp. was very different than old, had to re-route wires and lines. Held nitrogen for 30 minutes OK. Pulled vacuum, charge with 417C 3lbs. Unit is running 5.5 amps. Box is coming down to temp. Will check back.

Near Country Club Ln, State College, PA 16803
Service C.

Service C.

Checked and found ice machine locked out at controller, also controller buttons were pushed in on two of the buttons pulled buttons out so controller would work. Started freeze cycle, makes good ice in 24 minutes. Went into harvest, all ice dropped but machine did not come out of harvest. Cleaned photo eyes, ran test on eyes and board, found photo eyes out of range 2.2 udc to 2.5 udc eye reads 3.2 udc Scotsman manual recommends replacing eyes. Ran cleaner through machine. Cycled machine 4 times 24 minute freeze 5 minute 10 seconds harvest. Talked to Mark, he would like to watch machine before we replace eyes.

Near Cliffside Dr, State College, PA 16801
Service C.

Service C.

Removed faulty leaking t-stat. Installed new t-stat. Tested for leaks found none. Tested operation OK.

Near S Pugh St, State College, PA 16801