Mechanicsburg PA Commercial Refrigeration

K&D Factory Service has been providing factory authorized kitchen equipment parts and service to the businesses of Mechanicsburg, PA and the surrounding areas since 1945!

 

How do you fix a Blodgett convection oven near Mechanicsburg?

The following are the two most common problems that you may encounter and potential solutions to fix your Blodgett convection oven. 

Not heating up:

  • The power switch on the control panel is turned off. This may be fixed by setting the control panel to “cook” or “oven on.”
  • Open oven door(s). Check to see if one or both oven doors are open. Check to see whether the door is obstructed or if the gasket is filthy or broken. It's also possible that a faulty door gasket or hinge is keeping the door from shutting.

Convection fan not running:

  • Open oven door(s). An obstruction, a broken hinge, or a damaged gasket might cause the oven door to split open.
  • Activated convection fan delay. Some devices include a convection fan delay that can be turned on. Deactivating this function will prevent the fan from turning on once it has been delayed.
How do you troubleshoot a walk-in cooler near Mechanicsburg?

If your cooler isn't keeping the correct temperature, here are a few things to look for.

    • Check the cooler's thermostat to see whether it needs to be refrigerated; crank the dial up and down until you hear a clicking sound.
    • Ensure that the rear of the evaporator coil is clean and that there is adequate air movement.
    • Make that the condenser on the roof or above the walk-in cooler is operational.
    • Make sure the condenser coil isn't clogged with debris. If this is the case, switch off the unit and clean it.
  • Make sure the walk-in cooler door is completely closed.

If you’ve tried all of the above and are still having performance issues, contact a walk-in cooler repair specialist for additional help.

Why is my frymaster fryer not heating up?

Check the following if the fryer isn't heating:

  • Unplugged power cord - Reconnect the power cord if it has been knocked out of the outlet.
  • Drain safety valve open - Make sure the drain safety valve is fully closed if it is open.
  • Faulty controller - An authorized technician will need to inspect or repair this part.
  • You should also make sure the gas valve is turned all the way to the ON position on gas models.

If following these basic troubleshooting steps doesn’t solve the problem, your frymaster may need repair. Call a professional for a more in-depth diagnosis.

Why is my Blodgett oven not heating up in Mechanicsburg?

There could be several reasons why a Blodgett oven is not heating up. It could be due to a malfunctioning thermostat, a faulty heating element, a tripped circuit breaker, or a problem with the gas supply (if it's a gas oven). It is best to consult a professional technician or reach out to Blodgett's customer service for troubleshooting and repair assistance to determine the exact cause of the issue and resolve it effectively.

Where is the fuse on a blodgett oven?

The location of the fuse in a Blodgett oven can vary depending on the specific model and configuration. In some cases, the fuse may be located on the control panel or behind a removable panel on the oven. However, it is important to note that not all Blodgett ovens have user-accessible fuses. If you suspect a fuse issue with your Blodgett oven, it is recommended to consult the oven's manual or contact Blodgett's customer support for specific guidance on locating and replacing the fuse.

Where is the pilot light on a blodgett oven?

In most cases, the pilot light can be found near the burner assembly. It is usually a small flame that needs to be lit manually to ignite the oven. However, it's important to note that some modern Blodgett ovens may use electronic ignition systems instead of a traditional pilot light. To determine the exact location and operation of the pilot light on your specific Blodgett oven model, it is recommended to consult the oven's manual or contact Blodgett's customer support for assistance.

Read our reviews and find out why your colleagues call us when they need OEM parts and equipment or refrigeration repair services in Mechanicsburg, PA.

Recent Jobs and Reviews in Mechanicsburg, PA

Job Locations and Reviews

Ashley B.
Ashley B. Checked in
Commercial Kitchen Equipment Repair: Dealing with a malfunctioning motor in a frozen beverage machine, I repaired the motor. This fix ensures uninterrupted blending, providing customers with refreshing frozen drinks.
Mechanicsburg, PA
Ashley B.
Ashley B. Checked in
Commercial Ice Maker Installation. A hospitality facility needed a new ice maker for their high-demand ice requirements. We positioned the ice maker, connected the water and drain lines, and fine-tuned the ice production settings. Thorough testing confirmed efficient ice production, enhancing the facility's service.
Mechanicsburg, PA
Mark B.
Mark B. Checked in
Arrived on, 09/09/23- Steve- Call Out- Found unit to have tstat set to cooling and unit at 80 degrees. Went to roof and found compressor extremely hot and condennsing fan motor to hot to touch. Tried to turn u it on and tested fan motor. Fan did not spin freely. Replaced condensing fan motor and then had to cool compressor to turn back on. Turned u it on and tested. Unit is in operation at this time.
Mechanicsburg, PA 17055
Mark B.
Mark B. Checked in
Arrived on, 08/15/3- Matt- Cabinet was at 46 degrees when I arrived and the condenser fan was running but the compressor was hot and went off on overload. The condenser coil was clean so I put gauges on to check pressures. Pressures were low so I leak checked the unit and found the access valve on the compressor suction process tube was leaking. I replaced the access valve, changed the filter drier and pulled a vacuum on the system. I added refrigerant and waited for the unit to come down to temp and with the thermostat set at 4 it cycled off at 35 degrees. Unit is now cooling properly.
Mechanicsburg, PA 17055
Ashley B.
Ashley B. Checked in
Commercial Charbroiler Installation. Installing a commercial charbroiler for a commercial client, we ensured proper ventilation, gas connection, and heat distribution. Thorough tests guaranteed even cooking results.
Mechanicsburg, PA
Ashley B.
Ashley B. Checked in
Commercial Food Warmer Repair. The warming cabinet's temperature was fluctuating, impacting food quality. Our adept repairman meticulously examined the unit and determined a malfunctioning heating element as the root cause. The faulty element was expertly replaced, ensuring consistency and even warming throughout the cabinet.
Mechanicsburg, PA
Ashley B.
Ashley B. Checked in
Commercial Microwave Repair. A commercial microwave's timer malfunctioned, causing confusion in cooking durations. Our technician promptly replaced the timer unit, restoring precise cooking times for reheating and food preparation.
Mechanicsburg, PA 17055
Ashley B.
Ashley B. Checked in
Commercial Dishwasher Repair Service near W Main St. We were contacted by a commercial kitchen that had a malfunctioning dishwasher, which posed a great risk to the business's operations. We promptly arrived at their location and proceeded to examine the dishwasher to determine the cause of the performance issues. The examination uncovered the source of the problem to be a faulty water pump. I replaced the water pump to get the dishwasher back up and running quickly, ensuring smooth operations for the client. The client was appreciative of the quick response time and the efficiency of the repairs.
Mechanicsburg, PA
Ashley B.
Ashley B. Checked in
Commercial Kitchen Repair Service near W Locust St. Upon receiving a call from a commercial client regarding their malfunctioning commercial beer cooler, we promptly dispatched a technician for repairs. I swiftly arrived at the client's place of business and proceeded to diagnose the issue with their appliance. Through careful investigation, I identified the frozen temperature control unit as the underlying cause. To resolve the problem, I replaced the temperature control unit and conducted thorough testing to ensure it could maintain the required temperature accurately. The client expressed immense relief upon having a fully functional cooler for their business operations!
Mechanicsburg, PA
Mark B.
Mark B. Checked in
Commercial Kitchen Repair Service near E Allen St. When a commercial client was experiencing difficulties with their commercial convection oven, they contacted us for repairs. I quickly arrived at the place of business and assessed the issue with the client’s convection oven. The investigation led to the source of the problem being the appliance’s internal fan. The fan was inoperable and required replacing, so I replaced the internal fan to bring it back to working order. I tested the oven to ensure proper circulation and it was working well again upon my departure. The client was relieved to have a working oven for their business operations!
Mechanicsburg, PA
Mark B.
Mark B. Checked in
Arrived at location on 10/27/22 - Checked out unit and found that the main water fitting that goes into the three way valve was leaking. Pulled unit apart and resealed all the fittings. Reassembled and checked operation by running unit. Found nothing leaking at this time.
Mechanicsburg, PA 17050
Mark B.
Mark B. Checked in
Arrived at location on 8/1/22 - -Checked out unit and found that pilots were out so relit them and let heat up. Checked the temps and adjusted them. Checked operation, ok. Let cycle on and off, ok.
Mechanicsburg, PA 17050
Mark B.
Mark B. Checked in
Arrived at location on 6/3/22 - Customer was having to issue with coffee brewer tripping gfi outlet. Had customer brew pot of coffee no issues. I asked if it gets moisture back where unit sits and manager said it does. Removed bottom pot warmer and found wires to element showed that they were wet at one time. Customer gave me a sheet tray and I placed coffee brewer and grinder on top of it to help keep moisture away from warmer. All ok.
Mechanicsburg, PA 17050
Mark B.
Mark B. Checked in
Arrived at location on 1/11/22 - Checked out unit and found the water is by passing water valve and is leaking around the gauge. Will order and return. Returned to location on 1/13/22 - Arrived on site and spoke to mod. Verified that parts was correct and began to remove listed parts. After installing I checked for leaks and run dishes cycle multiple times. Rinse cycle had 20 psi. Unit is working at this time.
Mechanicsburg, PA 17055
Mark B.
Mark B. Checked in
Arrived at location on 8/27/21 - Checked the unit and found out that the elements on ohm were OL. I called manufacture and spoke to Mark and he confirmed that the unit parts were out of stock and were not made anymore. The unit is over 16 years old. Customer would like a quote for a new unit.
Mechanicsburg, PA 17055
Mark B.
Mark B. Checked in
Arrived at location on 7/14/21 - Checked out unit and found that the start button was working fine on arrival. Per customer the start button would stick in and not come back out. Tried starting and stopping several times and worked every time will obtain start and stop button and return. Returned to location on 7/23/21 - Returned with parts. Removed old stop and start switch and installed new stop and start switch. Checked operation, ok.
Mechanicsburg, PA 17055
Mark B.
Mark B. Checked in
Arrived on site on 7/14/21 - Checked out unit and found on arrival that the water symbol was on display and none of the valves were working. Found that the A2 fuse on the board was open. Ohmed out all the solenoids at 4 ohms and nothing to ground. Installed new fuse and ran unit and left cycle for a period of time, there's no problem. Unit ran at 100% steam and couldn’t get anything to fail. Recommend to run it without over night cooking to see if it fails again and what setting it is in. Could be one of the valves shorting out from time to time. Will call John at 8 or 9 to see what he would like to do.
Mechanicsburg, PA 17050
Mark B.
Mark B. Checked in
Arrived at location on 7/6/21 to check on walk in cooler. Unit had ice build up on evap. Thawed with hot water and started unit back up. Checked receiver and it is still at 80% checked super heat and it was at 35 degrees. Tried adjusting but unit would not respond. Will need to replace txt. Unit is R 22. Returned to location on 7/9/21 - picked up parts from supply house. Pumped unit down and removed old txv valve and brazed in new one. Suction pressure was higher and temperature dropped.
Mechanicsburg, PA 17050
Mark B.
Mark B. Checked in
Arrived at location on 6/17/21 and checked in with MOD. Customer complained unit not holding temp running at 60 degrees. Plugged unit in to outlet. Temp checked cabinet with digital thermometer. After 5 minutes unit pulled down to 38 degrees. Unit working properly at this time and making temp. Checked customer thermometer. Customer thermometer still reads 60 degrees. Recommend customer replace thermometer
Mechanicsburg, PA 17055
Service C.
Service C. Checked in
Came in and checked dishwasher ran it no issues removed side cover saw water leaking from back of unit. ran another cycle found vacuum breaker leaking when it goes into rinse cycle. will have part tomorrow morning and will return. 12-22-20 Returned with part. shut off water and dishwasher. removed vacuum breaker from dishwasher and removed pipes from vacuum breaker and installed them on new one. put new vacuum breaker in place and tightened down. ran 3 cycles to check for leaks, all okay.
Mechanicsburg, PA 17055
Service C.
Service C. Checked in
Found MAN ice machine and bin unplugged and water leaking from the ice bin, Bin parts were laying on top of the ice machine, and water was laying in the ice machine drain pan. Pulled drain line from drain and blew backwards then let it drain out.. removed ice. machine front cover and removed drain pan, vacuumed all sludge and blew drain out again, then vacuumed water from underneath and from the floor. Reassembled and turned on. Observed bin draining and machine harvest 2 sheets of ice. everything is working good at this time.
Mechanicsburg, PA 17055
Service C.
Service C. Checked in
Call Out - Reach-In Cooler Unit was 43° upon arrival. Found suction line at compressor bent and almost closed off. Straightened out line best possible and unit started working. Also found it slightly low on charge. Unit is cooling and going back down to temp. Everything is running fine at this time..
Mechanicsburg, PA 17055
Service C.
Service C. Checked in
Found Steamer top incoming water valve (condensate) leaking out of pinholes in plastic. all components under unit wet. found relay burnt cleaned to test but will need replaced. found flame sense going to ground will need new pilot and gasket. order qwp (expedited freight) per Jason. 6-30-20 Replaced valve, relay and pilot. tested, sys ops okay.
Mechanicsburg, PA 17050
Service C.
Service C. Checked in
Came in and upon arrival the Steamer unit was running. per customer he said this morning when the standby light came on then the reset the standby went off and came back again. he said it happened just once today and they drained the unit and filled it again and it works just fine. I drained the unit a couple of times and filled it and the unit works just fine, no issues. blew the yellow valve in case there is any residue of scale so it will go through the drain. left the unit running for a while with no problems, probably some was stuck somewhere and got drained. customer will gave us a call if the issue comes back again. asked customer if he wants us to delime the unit and he will call us to gave us his decision.
Mechanicsburg, PA 17055
Service C.
Service C. Checked in
Some of the wires in Oven unit are fried: Found no gas to bottom oven. quick disconnect not seated properly, reseated. tested okay. customer is going to repair top oven.
Mechanicsburg, PA 17050

Planned Maintenance

A planned maintenance agreement can keep your equipment running longer than the factory warranty. Reduce cost, downtime and have your equipment running at top performance when you need it most.

We Do It Right The 1st Time!

See what our customers think about our service!

Great service Very courteous polite and knowledgeable The Gardens At Stroud Stroudsburg
Super Guys! The K & D Team of repairman are super!. always courteous, friendly and get the job done right! Answer my questions and never a surprise cost. Dunmore Health Care Center Dunmore
Maintenance Supervisor Shawn is a good Devoted Service Tech from your Altoona Offfice Steve Long is always a great help when i call him Mount Union School District Mount Union
Read More