How do you fix a Blodgett convection oven near Mechanicsburg?

The following are the two most common problems that you may encounter and potential solutions to fix your Blodgett convection oven. 

Not heating up:

  • The power switch on the control panel is turned off. This may be fixed by setting the control panel to “cook” or “oven on.”
  • Open oven door(s). Check to see if one or both oven doors are open. Check to see whether the door is obstructed or if the gasket is filthy or broken. It's also possible that a faulty door gasket or hinge is keeping the door from shutting.

Convection fan not running:

  • Open oven door(s). An obstruction, a broken hinge, or a damaged gasket might cause the oven door to split open.
  • Activated convection fan delay. Some devices include a convection fan delay that can be turned on. Deactivating this function will prevent the fan from turning on once it has been delayed.
How do you troubleshoot a walk-in cooler near Mechanicsburg?

If your cooler isn't keeping the correct temperature, here are a few things to look for.

    • Check the cooler's thermostat to see whether it needs to be refrigerated; crank the dial up and down until you hear a clicking sound.
    • Ensure that the rear of the evaporator coil is clean and that there is adequate air movement.
    • Make that the condenser on the roof or above the walk-in cooler is operational.
    • Make sure the condenser coil isn't clogged with debris. If this is the case, switch off the unit and clean it.
  • Make sure the walk-in cooler door is completely closed.

If you’ve tried all of the above and are still having performance issues, contact a walk-in cooler repair specialist for additional help.

Why is my frymaster fryer not heating up?

Check the following if the fryer isn't heating:

  • Unplugged power cord - Reconnect the power cord if it has been knocked out of the outlet.
  • Drain safety valve open - Make sure the drain safety valve is fully closed if it is open.
  • Faulty controller - An authorized technician will need to inspect or repair this part.
  • You should also make sure the gas valve is turned all the way to the ON position on gas models.

If following these basic troubleshooting steps doesn’t solve the problem, your frymaster may need repair. Call a professional for a more in-depth diagnosis.

Why is my Blodgett oven not heating up in Mechanicsburg?

There could be several reasons why a Blodgett oven is not heating up. It could be due to a malfunctioning thermostat, a faulty heating element, a tripped circuit breaker, or a problem with the gas supply (if it's a gas oven). It is best to consult a professional technician or reach out to Blodgett's customer service for troubleshooting and repair assistance to determine the exact cause of the issue and resolve it effectively.

Where is the fuse on a blodgett oven?

The location of the fuse in a Blodgett oven can vary depending on the specific model and configuration. In some cases, the fuse may be located on the control panel or behind a removable panel on the oven. However, it is important to note that not all Blodgett ovens have user-accessible fuses. If you suspect a fuse issue with your Blodgett oven, it is recommended to consult the oven's manual or contact Blodgett's customer support for specific guidance on locating and replacing the fuse.

Where is the pilot light on a blodgett oven?

In most cases, the pilot light can be found near the burner assembly. It is usually a small flame that needs to be lit manually to ignite the oven. However, it's important to note that some modern Blodgett ovens may use electronic ignition systems instead of a traditional pilot light. To determine the exact location and operation of the pilot light on your specific Blodgett oven model, it is recommended to consult the oven's manual or contact Blodgett's customer support for assistance.

Read our reviews and find out why your colleagues call us when they need OEM parts and equipment or refrigeration repair services in Mechanicsburg, PA.

Local Reviews
for Mechanicsburg, PA



Mark B.

Mark B.

Arrived at location on 10/27/22 - Checked out unit and found that the main water fitting that goes into the three way valve was leaking. Pulled unit apart and resealed all the fittings. Reassembled and checked operation by running unit. Found nothing leaking at this time.

Near Carlisle Pike, Mechanicsburg, PA 17050
Mark B.

Mark B.

Arrived at location on 8/1/22 - -Checked out unit and found that pilots were out so relit them and let heat up. Checked the temps and adjusted them. Checked operation, ok. Let cycle on and off, ok.

Near Grandon Way, Mechanicsburg, PA 17050
Mark B.

Mark B.

Arrived at location on 6/3/22 - Customer was having to issue with coffee brewer tripping gfi outlet. Had customer brew pot of coffee no issues. I asked if it gets moisture back where unit sits and manager said it does. Removed bottom pot warmer and found wires to element showed that they were wet at one time. Customer gave me a sheet tray and I placed coffee brewer and grinder on top of it to help keep moisture away from warmer. All ok.

Near Carlisle Pike, Mechanicsburg, PA 17050
Mark B.

Mark B.

Arrived at location on 1/11/22 - Checked out unit and found the water is by passing water valve and is leaking around the gauge. Will order and return. Returned to location on 1/13/22 - Arrived on site and spoke to mod. Verified that parts was correct and began to remove listed parts. After installing I checked for leaks and run dishes cycle multiple times. Rinse cycle had 20 psi. Unit is working at this time.

Near E Main St, Mechanicsburg, PA 17055
Mark B.

Mark B.

Arrived at location on 8/27/21 - Checked the unit and found out that the elements on ohm were OL. I called manufacture and spoke to Mark and he confirmed that the unit parts were out of stock and were not made anymore. The unit is over 16 years old. Customer would like a quote for a new unit.

Near Westport Dr, Mechanicsburg, PA 17055
Mark B.

Mark B.

Arrived at location on 7/14/21 - Checked out unit and found that the start button was working fine on arrival. Per customer the start button would stick in and not come back out. Tried starting and stopping several times and worked every time will obtain start and stop button and return. Returned to location on 7/23/21 - Returned with parts. Removed old stop and start switch and installed new stop and start switch. Checked operation, ok.

Near Lancaster Blvd, Mechanicsburg, PA 17055
Mark B.

Mark B.

Arrived on site on 7/14/21 - Checked out unit and found on arrival that the water symbol was on display and none of the valves were working. Found that the A2 fuse on the board was open. Ohmed out all the solenoids at 4 ohms and nothing to ground. Installed new fuse and ran unit and left cycle for a period of time, there's no problem. Unit ran at 100% steam and couldn’t get anything to fail. Recommend to run it without over night cooking to see if it fails again and what setting it is in. Could be one of the valves shorting out from time to time. Will call John at 8 or 9 to see what he would like to do.

Near Carlisle Pike, Mechanicsburg, PA 17050
Mark B.

Mark B.

Arrived at location on 7/6/21 to check on walk in cooler. Unit had ice build up on evap. Thawed with hot water and started unit back up. Checked receiver and it is still at 80% checked super heat and it was at 35 degrees. Tried adjusting but unit would not respond. Will need to replace txt. Unit is R 22. Returned to location on 7/9/21 - picked up parts from supply house. Pumped unit down and removed old txv valve and brazed in new one. Suction pressure was higher and temperature dropped.

Near Carlisle Pike, Mechanicsburg, PA 17050
Mark B.

Mark B.

Arrived at location on 6/17/21 and checked in with MOD. Customer complained unit not holding temp running at 60 degrees. Plugged unit in to outlet. Temp checked cabinet with digital thermometer. After 5 minutes unit pulled down to 38 degrees. Unit working properly at this time and making temp. Checked customer thermometer. Customer thermometer still reads 60 degrees. Recommend customer replace thermometer

Near Gateway Dr, Mechanicsburg, PA 17055
Service C.

Service C.

Came in and checked dishwasher ran it no issues removed side cover saw water leaking from back of unit. ran another cycle found vacuum breaker leaking when it goes into rinse cycle. will have part tomorrow morning and will return. 12-22-20 Returned with part. shut off water and dishwasher. removed vacuum breaker from dishwasher and removed pipes from vacuum breaker and installed them on new one. put new vacuum breaker in place and tightened down. ran 3 cycles to check for leaks, all okay.

Near Arthur Ave, Mechanicsburg, PA 17055
Service C.

Service C.

Found MAN ice machine and bin unplugged and water leaking from the ice bin, Bin parts were laying on top of the ice machine, and water was laying in the ice machine drain pan. Pulled drain line from drain and blew backwards then let it drain out.. removed ice. machine front cover and removed drain pan, vacuumed all sludge and blew drain out again, then vacuumed water from underneath and from the floor. Reassembled and turned on. Observed bin draining and machine harvest 2 sheets of ice. everything is working good at this time.

Near Arthur Ave, Mechanicsburg, PA 17055
Service C.

Service C.

Call Out - Reach-In Cooler Unit was 43° upon arrival. Found suction line at compressor bent and almost closed off. Straightened out line best possible and unit started working. Also found it slightly low on charge. Unit is cooling and going back down to temp. Everything is running fine at this time..

Near Arthur Ave, Mechanicsburg, PA 17055
Service C.

Service C.

Found Steamer top incoming water valve (condensate) leaking out of pinholes in plastic. all components under unit wet. found relay burnt cleaned to test but will need replaced. found flame sense going to ground will need new pilot and gasket. order qwp (expedited freight) per Jason. 6-30-20 Replaced valve, relay and pilot. tested, sys ops okay.

Near Carlisle Pike, Mechanicsburg, PA 17050
Service C.

Service C.

Came in and upon arrival the Steamer unit was running. per customer he said this morning when the standby light came on then the reset the standby went off and came back again. he said it happened just once today and they drained the unit and filled it again and it works just fine. I drained the unit a couple of times and filled it and the unit works just fine, no issues. blew the yellow valve in case there is any residue of scale so it will go through the drain. left the unit running for a while with no problems, probably some was stuck somewhere and got drained. customer will gave us a call if the issue comes back again. asked customer if he wants us to delime the unit and he will call us to gave us his decision.

Near Heinz St, Mechanicsburg, PA 17055
Service C.

Service C.

Some of the wires in Oven unit are fried: Found no gas to bottom oven. quick disconnect not seated properly, reseated. tested okay. customer is going to repair top oven.

Near Grandon Way, Mechanicsburg, PA 17050
Service C.

Service C.

checked out Combi Oven unit and found that the sc pump was not running in test mode. drained generator and pulled off pump to find that pump was blocked with lime. cleaned out lime and flushed pump. also found that the drain hose from the pump is leaking. customer is going to replace hose. all other operation okay.

Near Carlisle Pike, Mechanicsburg, PA 17050
Service C.

Service C.

Found contactor on Ice Machine bad, replaced from truck stock and watched unit drop one batch of ice, Unit is working properly at this time, Unit does need cleaned but don't have time today, will have to return to clean

Near W Main St, Mechanicsburg, PA 17055
Service C.

Service C.

Everything on Prep Table unit running properly when I arrived, Found unit to be low on refrigerant, dropped what was left and recharged with factory amount of 134A, checked for leaks with leak detector and bubbles but could not find any, Leak maybe in the cold plate which is not repairable, Unit is dropping in temperature and working properly at this time

Near Shadow Oaks Dr, Mechanicsburg, PA 17050
Service C.

Service C.

found faults on TBC Oven as follows: F6=EC Temp(electrical controls)156; F5=Mag Temp 16; F2=Lo Temp(cook cavity) 2; F1=Main Blower 1. Cleared all. Inspected control compartment and found signs of excessive component heat stress. Controls are very dirty. All fuse holders cracked, good mag amp draw, but blower control and blower need replaced. Also possible other issues. Per Cust(Dee) DNR. Replaced side panel and left breaker off.

Near Carlisle Pike, Mechanicsburg, PA 17050
Service C.

Service C.

Checked Fryer-Electric unit and found that unit had grill clip in fryer drain on first vat on left. had to remove drain pipe and open actuator to free up grill clip. pulled out clip and put fryer back together, all okay. ***Travel on WO# 183849

Near Wesley Dr, Mechanicsburg, PA 17055
Service C.

Service C.

Checked Gas Fryer unit and found that basket holder was pulling through back plate causing basket holder to fall down. removed basket holder bolts and speed nuts and put on fender washer, lock washer and 7/16 nut on both sides to reinforce basket holder. tested operation making sure that baskets would hold, all okay.

Near Arthur Ave, Mechanicsburg, PA 17055
Service C.

Service C.

Checked out all HVACR equipment.

Near Wesley Dr, Mechanicsburg, PA 17055
Service C.

Service C.

Found Ice Machine evaporator had frozen up so we cleared the ice and checked operation. The cube deflector was out of position and causing ice to back up, but it's hard to say if that caused the freeze up or if it shifted because of the ice pushing it. We re-positioned the deflector but it also has busted slats which can sometimes break off and make their way through the hoses and cause issues with the distributors, pump or float switch. Put ice up to the bin stat bulb and it shut the machine down like it should. Pressures looked good and machine dropped 3 batches of ice with all cubes falling before the next freeze cycle starts. Unit is now working properly but I will order a new cube deflector. ****mileage and travel on work order #179411*** 4/15/19 Unit bin was full and unit shut down when I arrived, Replaced cube guide and emptied some ice from bin to ensure unit is working, unit is working properly at this time.

Near Shadow Oaks Dr, Mechanicsburg, PA 17050
Service C.

Service C.

Followed customer concerns. inspected Reach-In Cooler unit, it was too warm. checked amp draw of the compressor. it goes between 5.8 and 6.4 amps. comp is too hot can not touch it more than 2 seconds. checked pressures found low in charge. added r404a. got pressures where they should be. but compressor goes internal overload. spoke with customer Don Eyler. overall unit not worth repair. Don wants a quote for a new unit.

Near S Filbert St, Mechanicsburg, PA 17055
Service C.

Service C.

Came in with new gas fryer and removed old one, installed new and checked operation, okay

Near Arthur Ave, Mechanicsburg, PA 17055

Planned Maintenance

A planned maintenance agreement can keep your equipment running longer than the factory warranty. Reduce cost, downtime and have your equipment running at top performance when you need it most.

We Do It Right The 1st Time!

See what our customers think about our service!

Great service Very courteous polite and knowledgeable The Gardens At Stroud Stroudsburg
Super Guys! The K & D Team of repairman are super!. always courteous, friendly and get the job done right! Answer my questions and never a surprise cost. Dunmore Health Care Center Dunmore
Maintenance Supervisor Shawn is a good Devoted Service Tech from your Altoona Offfice Steve Long is always a great help when i call him Mount Union School District Mount Union
Read More