Customer Comments: 3-10-20 BOTTOM -- not working: 3-11-20 Upon arrival top was steaming, bottom was not, site glass full of water, heat contactor not pulled in, drained unit, checked both hi limits - okay, unit filled and heated, possible stuck heat contactor on lower chamber replaced and tested 47 amps per leg, all okay.

Near Manor Dr, Stroudsburg, PA 18360
Service C.

Service C.

Replaced Cleveland steamer elements / limits bottom compartment and top and bottom probe housing and bottom stand by thermostat, then delimed both unit, customer supplied delimer acid

Near Manor Dr, Stroudsburg, PA 18360
Service C.

Service C.

Found Steamer top compartment elements shorted out - all of them, need elements hi limits probe housing, will get prices. Note: quoting additional repairs, closing out this work order.

Near Manor Dr, Stroudsburg, PA 18360
Service C.

Service C.

Tested the CLE Kettle unit and found the control cover was loose causing it to short to the contactor. Dropped the covers and tightened the nut holding the covers stable. Tested and the unit is heating.

Near Manor Dr, Stroudsburg, PA 18360
Service C.

Service C.

Found unit filled okay but would not heat, found water control / heat board not letting power through to heat circuit, replaced board and tested okay

Near Possinger Dr, Stroudsburg, PA 18360
Service C.

Service C.

Toaster not heating: buns are toasting but customer claims they are not hot enough, went into adjustments, found bun setting slightly less than middle, adjusted up for darker setting and tested - they approved this change, tested with several buns, all okay.

Near Main St, Stroudsburg, PA 18360
Service C.

Service C.

examined Kettle unit, opened bottom pan where sparks came from, found contactor blown up, removed and replaced and tested, drawing 23.5 amps per leg, all okay

Near Manor Dr, Stroudsburg, PA 18360
Service C.

Service C.

Found Food Warmer controllers were rated 120v, supplied 208. Mfg sending new controllers to shop. Find breaker for unit, plug does not come apart. EMERGENCY CALL OUT 11/11/19 Found wires in breaker panel wrong, hot going to neutral and neutral going to l3. Shipping controllers out today for tomorrow. 11/12/19 Removed old temp controls and replaced with new wired and tested all 3 working met with Joe the deli manager on duty all controls were at 200'f reset to 165'f per Joe showed customer how to adjust set point made sure all 3 reached set point and cycled on/off all okay.

Near Stroud Mall Rd, Stroudsburg, PA 18360
Service C.

Service C.

examined Skillet unit found center element not heating opened control panel checked wires and contactors ok tilted unit removed cover found broken wire and element end put together with splice will order new element, also bring some insulated 10 or 12 wire and ring terminals. 10/22/19 opened bottom replaced center element used new wire and terminals and tested all okay.

Near Manor Dr, Stroudsburg, PA 18360
Service C.

Service C.

examined VHL Steamer Elec unit - off upon arrival - removed panels and turned on, took forever and did not fill. Removed and cleaned probes, all looked good, removed filtered water supply line - lots of pressure (gauge shows 50 psi). Disconnected fill line from generator, barely getting any water, confirmed with Rachel, unit takes forever on initial fill and stops steaming when in use. This means low water flow, found dual fill valve bad and will replace. QWP (expedited freight) PARTS PER RACHEL. 8/29/19 Replaced water valve, unit filled and heated, all okay.

Near Manor Dr, Stroudsburg, PA 18360
Service C.

Service C.

examined Holding Cabinet unit, 2 lower slots front and 2 lower slots rear need new touch pads, will order and return. 6-6-19 replaced by lower front and rear bezels, assembled and tested, all okay.

Near Main St, Stroudsburg, PA 18360
Service C.

Service C.

Customer requested both Clamshell plattens calibrate, right side show in platten jammed, found grease build up tripping travel limit switch - cleaned this area only. Finished calibration and tested with hot off the grill beef, all okay.

Near Main St, Stroudsburg, PA 18360
Service C.

Service C.

Examined unit. Found on and running. Manager stated after a heavy lunch, error comes up. Examined unit. Found module sparking like unit not sensing flame and a very weak spark. Will order flame sensor and also ignition module and return. 1-3-17 Upon arrival, unit in use. Removed flame sensor, new one not the same. Cleaned old one and reused. Found break in protective coating on sense wire and taped up. Put in new ignition module, turned unit on. Sparked and ignited, sensed flame right away. Came up to full temp, shut down. Ran product, cycled on/off. All okay.

Near N 9th St, Stroudsburg, PA 18360
Service C.

Service C.

Performed complete grill certification. Left side error reed switch. Found loose wire from board to contactor because of grease migration. Repairs were authorized. Excessively dirty, cleaning was authorized.

Near N 9th St, Stroudsburg, PA 18360
Service C.

Service C.

Performed complete certification. Replaced seals, adjusted and calibrated as needed. All okay.

Near Main St, Stroudsburg, PA 18360
Service Check-In ..

Service Check-In ..

Garland Clamshell Tech - Left platen disabled upon arrival. Enabled platen, tried to calibrate, would not. Removed rear covers, found lower switch bad, replaced. Calibrated platen and calibrated reed switches. Tested with product temps and finished ok. All ok

Near N 9th St, Stroudsburg, PA 18360